Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques.
Loading...
Date
Authors
Kocaagaoglu, Hasan
Albayrak, Haydar
Sahin, Sezgi Cinel
Gurbulak, Aysegul Guleryuz
Journal Title
Journal ISSN
Volume Title
Publisher
Open Access Color
GOLD
Green Open Access
Yes
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
PURPOSE: The purpose of this in vitro study was to evaluate the marginal misfits of three-unit frameworks fabricated with conventional and digital impressions techniques. MATERIALS AND METHODS: Thirty brass canine and second premolar abutment preparations were fabricated by using a computer numerical control machine and were randomly divided into 3 groups (n=10) as follows: conventional impression group (Group Ci), Cerec Omnicam (Group Cdi), and 3shape TRIOS-3 (Group Tdi) digital impression groups. The laser-sintered metal frameworks were designed and fabricated with conventional and digital impressions. The marginal adaptation was assessed with a stereomicroscope at ×30 magnification. The data were analyzed with 1-way analysis of variances (ANOVAs) and the independent simple t tests. RESULTS: A statistically significant difference was found between the frameworks fabricated by conventional methods and those fabricated by digital impression methods. Multiple comparison results revealed that the frameworks in Group Ci (average, 98.8 ± 16.43 µm; canine, 93.59 ± 16.82 µm; premolar, 104.10 ± 15.02 µm) had larger marginal misfit values than those in Group Cdi (average, 63.78 ± 14.05 µm; canine, 62.73 ± 13.71 µm; premolar, 64.84 ± 15.06 µm) and Group Tdi (average, 65.14 ± 18.05 µm; canine, 70.64 ± 19.02 µm; premolar, 59.64 ± 16.10 µm) (P=.000 for average; P=.001 for canine; P<.001 for premolar). No statistical difference was found between the marginal misfits of canine and premolar abutment teeth within the same groups (P>.05). CONCLUSION: The three-unit frameworks fabricated with digital impression techniques showed better marginal fit compared to conventional impression techniques. All marginal misfit values were clinically acceptable.
Description
Keywords
Marginal misfit, Three-unit framework, Conventional impression, 617, Computeraided design / Computer-aided manufacturing, 610, Digital impression, Original Article
Fields of Science
03 medical and health sciences, 0302 clinical medicine
Citation
WoS Q
Scopus Q

OpenCitations Citation Count
7
Volume
11
Issue
5
Start Page
262
End Page
270
Collections
PlumX Metrics
Citations
Scopus : 8
PubMed : 3
Captures
Mendeley Readers : 42
SCOPUS™ Citations
8
checked on Jun 08, 2026
Web of Science™ Citations
6
checked on Jun 08, 2026
Page Views
63
checked on Jun 08, 2026
Downloads
45
checked on Jun 08, 2026
Google Scholar™