Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/10065
Title: What is the effect of optimum independent parameters on solar heating systems?
Authors: Kaçan, Erkan.
Ulgen, K.
Keywords: Central Composite Design (CCD)
Environmental efficiency
Exergy analysis
Response surface methodology (RSM)
Solar Combisystem
Solar heating
Efficiency
Environmental management
Solar collectors
Solar equipment
Solar radiation
Surface properties
Central composite designs
Exergy Analysis
Response surface methodology
Solar combisystems
Collector efficiency
Publisher: Elsevier Ltd
Abstract: Abstract Researchers are rather closely involved in Solar Combisystems recently, but there is lack of study that presents the optimum design parameters. Therefore, in this study the influence of the four major variables, namely; outside, inside temperature, solar radiation on horizontal surface and instantaneous efficiency of solar collector on the energetic, exergetic and environmental efficiencies of Solar Combisystems are investigated and system optimization is done by a combination of response surface methodology. Measured parameters and energetic-exergetic and environmental performance curves are found and statistical model is created parallel with the actual data. It is found that statistical model is significant and all "lack-of-fit" values are non-significant. Thus, it is proved that statistical model strongly represents the design model. Outside temperature, solar radiation on horizontal surface and instantaneous efficiency of solar collector are the decisive parameters for all responses but instantaneous efficiency of solar collector is not for environmental efficiency. Maximum exergetic efficiency exceeded 11%, maximum environmental efficiency reached up to 95% at optimized process. The optimum value of the outside temperature and solar radiation are found as 22°C and 773 W/m2 for all responses, on the other hand optimum collector efficiency is found around 60% for energetic and exergetic efficiency values. Inside temperature is not a decisive parameter for all responses. © 2015 Elsevier Ltd.
URI: https://hdl.handle.net/11499/10065
https://doi.org/10.1016/j.enconman.2015.07.052
ISSN: 0196-8904
Appears in Collections:Denizli Teknik Bilimler Meslek Yüksekokulu Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

SCOPUSTM   
Citations

8
checked on Mar 29, 2025

WEB OF SCIENCETM
Citations

7
checked on Mar 31, 2025

Page view(s)

522
checked on Mar 4, 2025

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.