Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/10384
Title: The place of D-dimer and L-lactate levels in the early diagnosis of acute mesenteric ischemia
Authors: Aydin, B.
Özban, Murat
Serinken, M.
Kaptanoğlu, Bünyamin
Demirkan, Neşe Çallı
Aydin, C.
Keywords: Acute mesenteric ischemia
D-dimer
L-lactate
biological marker
fibrin degradation product
fibrin fragment D
lactic acid
animal
early diagnosis
male
mesenteric ischemia
metabolism
rat
Wistar rat
Animals
Biological Markers
Early Diagnosis
Fibrin Fibrinogen Degradation Products
Lactic Acid
Male
Mesenteric Ischemia
Rats
Rats, Wistar
Publisher: Comenius University
Abstract: INTRODUCTION: Acute mesenteric ischemia (AMI) is an abdominal-vascular emergency which is rare and has high mortality rates (60-80 %) due to late diagnosis (1-3). Although it is known that extravascular reasons like intestinal intussusception, volvulus, strangulated hernias and obstructions can cause intestinal gangrene, these are rarely the cause of AMI (1). MATERIALS AND METHODS: In this study, we used male Wistar-Albino rats weighing 250-300 grams obtained from Pamukkale University Experimental Research Laboratory. Animals were exposed to light-dark cycles for 12 hours and had free access to food and water. They were kept in cages for 7 days to stabilise their intestinal flora. In animals of group I, nothing was made other than taking 0.5 ml blood intracardially. In other animals, abdomen was reached with midline laparotomy and superior mesenteric artery (SMA) was located. In group II (operative control group), SMA was isolated and manipulated but was not ligated. In Group III (intestinal ischemia group), SMAwas isolated and ligated with 3/0 silk tie distally to the aorta. After this process, intestinal ischemia was achieved which was confirmed by paleness and pulselessness of intestines, caecum and right colon. Later on, abdomen was closed with double 3/0 polyglactin sutures. At postoperative 1st, 4th and 6th hours 0.5 ml blood was taken intracardially from the animals in groups II and III in order to quantify D-dimer and L-lactate levels. LABORATORY TESTS: D-dimer: Blood samples which were put into tubes containing sodium citrate, were seperated from plasma with centrifugation at 4000 rpm for 7 minutes. L-lactate: Blood L-lactate levels were determined from blood taken into capillary tubes with the help of immobilised enzyme electrode technology using YSI 1500 Sport portative lactate analyzer (Yellow Springs Instruments Inc., Ohio-USA). HISTOPATHOLOGIC VERIFICATION: Two cm long intestinal samples were taken from animals in which SMA was ligated in order to achieve mesenteric ischemia and these samples were fixed in 10 % formol. DISCUSSION: As a result, in rats with SMA occlusion serum D-dimer levels were not increased significantly when compared either in the group or with the basal values of the control group and values in operative control group. Therefore, it is concluded that D-dimer is not a useful marker for early diagnosis of AMI. On the other hand, it is revealed that blood L-lactate levels began to increase significantly following 4th hour of mesenteric ischemia and it is shown that this increase continued at the 6th hour. In addition, considering the utmost importance of the early diagnosis in patients with the clinical suspicion of AMI, L-lactate seems to be a suitable marker to use in emergency departments because it is achieved with a portable device that gives fast and accurate results. Nevertheless, our results are need to be supported by clinical studies with larger patient series (Tab. 2, Fig. 11, Ref. 39). Text in PDF www.elis.sk.
URI: https://hdl.handle.net/11499/10384
https://doi.org/10.4149/BLL_2015_094
ISSN: 0006-9248
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
murat Özban.pdf144.28 kBAdobe PDFView/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

14
checked on Dec 21, 2024

WEB OF SCIENCETM
Citations

12
checked on Dec 19, 2024

Page view(s)

108
checked on Aug 24, 2024

Download(s)

392
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.