Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/1482
Title: Klorür katkılı polipirolün eser düzeydeki bakırın katı faz ekstraksiyonunda kullanımı
Other Titles: Use of chloride doped polypyrrole in the solid phase extraction of at trce level copper
Authors: Sönmez, Saygın
Advisors: Latif Elçi
Keywords: Bakır
Su Örnekleri
Klorür Katkılı Polipirol
Pirokatesol Viyolet
Katı Faz Ekstraksiyonu
Copper
Water Samples
Polypyrrole-Chloride
Pyrocatechol Violet
Solid Phase Extraction
Publisher: Pamukkale Üniversitesi Fen Bilimleri Enstitüsü
Abstract: Bu tezde, bakırın alevli atomik absorpsiyon spektrometrisi ile tayininden önce katı faz ekstraksiyonuyla önderiştirilmesi için yeni bir adsorban olarak klorür katkılı polipirol kullanımı çalışıldı. Yeni kullanılan adsorban, pH 4-7 aralığında bakırın anyonik şelatı olan Cu(pirokateşol viyolet)22- kompleksine yüksek seçicilik gösterdi. Bakır(II), Cu(pirokateşol viyolet)22 anyonik şelatı olarak, 1.0 g PPyCl kolonunda alıkonuldu ve 3 mL 2 M HNO3 ile kantitatif olarak elüe edildi. Kalibrasyon grafiği, gözlenebilme sınırının yakınından en az 50 µg/L'e kadar (r2= 0,999) doğrusaldır. Yöntem, çeşme suyu, atık su ve Karahayıt kaplıca suyuna uygulanmasıyla yüksek kesinlik (bağıl standart sapma <% 4) ve düşük gözlenebilme sınırıyla (0.87 µg/L) sırasıyla % 96, % 101, % 95 geri kazanım elde edildi. Yöntemin doğruluğunun sağlanması için, yöntem standart referans madde BCR 715 atık su-SRM'e uygulandı. Bağıl hata %+3.33 bulundu. Geliştirilen yöntem çeşme suyu, atık su ve Karahayıt kaplıca suyunda bakırın tayinine başarı ile uygulandı.
In this thesis, polypyrrole-chloride was studied as a new sorbent for preconcentration of copper(II) using solid-phase extraction prior to determination by flame atomic absorption spectrometry. The sorbent showed an extremely high selectivity towards copper(II) as an anionic chelate, i.e Cu(pyrocatechol violet)2 2- in the pH range of 4–7. Copper(II) as Cu(pyrocatechol violet)2 2- was selectively retained on a column containing 1.0g of polypyrrole-chloride and quantitatively eluted by 3 mL of 2.0 mol L-1 nitric acid. The calibration graph was linear with a correlation coefficient of 0.999 at levels near the detection limit and up to at least 50 ?g L?1. When applied for preconcentration and determination of copper in tap water, waste water and hot spring water, the recoveries were found to be 96, 101 and 95%, respectively, with high precision (% relative standard deviation < 4%) and low detection limit (0.87 ?g L?1). Verification of the accuracy was carried out by the analysis of a standard reference material (BCR 715 wastewater-SRM). The relative error was +3.33 %. The proposed method was successfully applied to the determination of copper in tap water, waste water and hot spring water samples.
URI: https://hdl.handle.net/11499/1482
Appears in Collections:Tez Koleksiyonu

Files in This Item:
File Description SizeFormat 
Saygın Sönmez.pdf1.09 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

Page view(s)

182
checked on Aug 24, 2024

Download(s)

136
checked on Aug 24, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.