Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/1483
Title: Altın-APDC birlikte çöktürme yöntemiyle bazı eser elementlerin deriştirilmesi ve AAS ile tayinleri
Other Titles: Preconcentration some trace metals with gold-APDC coprecipitation and atomic absorption spectrometric determinations
Authors: Gülmez, Şefika
Advisors: Ümit Divrikli
Keywords: Altın-Pirolidinditiyokarbamat
Birlikte Çöktürme
Atomik Absorpsiyon Spektrometresi
Gold-Pirolidindithiocarbamate
Co-Precipitation
Atomic Absorption Spectrometry
Publisher: Pamukkale Üniversitesi Fen Bilimleri Enstitüsü
Abstract: Bu çalışmada, altın-pirolidinditiyokarbamat ile birlikte çöktürme yöntemi, Cu, Ni ve Cd’un alevli AAS ile tayinleri için geliştirildi. Analitik parametreler olarak örnek çözeltisinin pH’ı, taşıyıcı element miktarı ve yabancı iyonların etkisi incelendi. Altın-PDC ile birlikte çöktürme sistemi ile pH 5’te Cu(II), Ni(II) ve Cd(II) için yeterli geri kazanma değerleri elde edildi. Geliştirilen yöntem içme suyu, atık su ve kekik suyu örneklerinin analizine uygulandı. Bu çalışmada bulunan sonuçların doğruluğu standart referans madde (BCR 715) analizi ile kontrol edildi. Ortalama geri kazanma değerleri % 97.6-101.2 aralığında değişirken, bağıl standard sapma değerleri % 1.2-2.2 aralığında değişmektedir. Alevli AAS ile tayinlerde gözlenebilme sınırları Cu(II), Ni(II) ve Cd(II) için sırasıyla 1,07g/L, 1,07g/L ve 0,03g/L olarak bulunmuştur (3s, N=10).
In this study, a gold-pirolidindithiocarbamate co-precipitation method was developed for the determination of trace amounts of Cu ,Ni and Cd by FAAS. Several analytical parameters governing the efficiency of the co-precipitation method were evaluated including pH of sample solution and amount of carrier element. Also, the effect of interfering matrix ions were examined. Recoveries at pH 5 were sufficient for Cu(II), Ni(II), and Cd(II) with gold-PDC co-precipitation system. The developed method was applied to the analysis of the drinking and waste waters and kekik water. The procedure was validated by the analysis of standard reference material (BCR 715). The average recoveries were in the range of % 97.6-101.2 % and the relative standard deviations were in the range of 1.2-2.2 %. The detection limits for Cu(II), Ni(II) and Cd(II) in the determination by FAAS (3s, N=10) were found to 1,07g/L, 1,07g/L and 0,03g/L, respectively.
URI: https://hdl.handle.net/11499/1483
Appears in Collections:Tez Koleksiyonu

Files in This Item:
File Description SizeFormat 
Şefika Gülmez.pdf6.14 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

Page view(s)

82
checked on May 27, 2024

Download(s)

1,714
checked on May 27, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.