Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/1769
Title: Jeotermal sistemlerde flash buhar ve bınary sistemlerin birlikte kullanımının enerji ve ekserji analizi
Other Titles: Energy and exergy analysis on geothermal systems of usage of flash vapor and binary systems in conjunction
Authors: Süren, Hatice
Advisors: Harun Kemal Öztürk
Keywords: Bereket Jeotermal Santrali
Zorlu Kızıldere Jeotermal Santrali
Binary Çevrim
Ekserjetik Verim
Flash Buhar Santrali
Elektrik Üretimi
Enerji
Bereket Geothermal Power Plant
Zorlu-Kızıldere Geothermal Power Plant
Binary Cycle
Exergetic Efficiency
Flash Steam Power Plants
Electricity Generation
Energy
Publisher: Pamukkale Üniversitesi Fen Bilimleri Enstitüsü
Abstract: Bu çalışmada, binary ve flash buhar çevrim santrallerinden bahsedilmiş, var olan donanımlar tanıtılmış; sistemin ve donanımlarının termodinamiğin birinci ve ikinci yasalarına göre enerji ve ekserji hesaplama denklemleri gösterilmiştir. Denizli Bereket Enerji Binary Jeotermal Santrali ve Denizli Zorlu Kızıldere Flash Buhar Jeotermal Santrali tanıtılmış, sahaların özellikleri ve santrallerin akış özellikleri ve donanımları hakkında bilgi verilmiştir. Ekserji analizinin amacı jeotermal güç santrallerini tanımlamak ve ekserji kayıplarını hesaplamaktır ayrıca Denizli Bereket Enerji Binary Jeotermal Santrali ve Denizli Zorlu Kızıldere Flash Buhar Jeotermal Santrali'nin birleştirildiği varsayılarak bu doğrultuda ekserji hesaplamaları yapılmıştır. Böylece kayıpların nerelerde yoğunlaştığı, jeotermal sahalara göre ayrı ayrı saptanarak performans artırımı yapılabilmektir.
In this research; Binary and Flash steam cycle power plant has been mentioned, the existing equipments have been introduced, the equations of energy and exergy calculations according to 1st and 2nd Law of thermodynamics of the system and equipments have been showed. Denizli Bereket Energy Binary Geothermal Power Plant and Denizli Zorlu Kızıldere Flash Steam Geothermal Power Plant have been determined and information about the features of the plants and flow specifications and equipments has been given. The main objective of exergy analysis is to determine the geothermal power plants and calculate exergy loss of the system. These two systems have been assumed to be integrated and the calculations have been made following this way. As a result of this whereas the losses condensed have been examined and separately for geothermal plants to increase the performances of the plants.
URI: https://hdl.handle.net/11499/1769
Appears in Collections:Tez Koleksiyonu

Files in This Item:
File Description SizeFormat 
Hatice Süren.pdf4.2 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

Page view(s)

218
checked on Aug 24, 2024

Download(s)

112
checked on Aug 24, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.