dc.description.abstract | The atmospheric sulfur dioxide (SO2) concentrations were determined by performing simultaneous sampling and analysis with West-Gaeke and hydrogen peroxide (H2O2) methods at Pamukkale University Kinikli Campus. In the spring of 2015, average SO2 concentrations were found to be 19.7 +/- 16.1, 62.8 +/- 22.0 and 20.6 +/- 40.3 mu g/cubic meter for the West-Gaeke and H2O2 methods and for the Denizli 1 air quality monitoring station, respectively. The SO2 concentrations obtained by the West-Gaeke method are lower than the values determined by the H2O2 method. When the statistical relation of the SO2 data set obtained by two different methods in this study is examined, it is seen that the regression coefficients are 0.21 for the linear trend and 0.25 for the polynomial trend. It has been found that the SO2 concentrations obtained by the H2O2 method are higher than the SO2 concentrations of the Denizli 1 air quality monitoring station and the SO2 concentrations determined by the West-Gaeke method do not show a distinct change with the SO2 concentrations of the air quality monitoring station. The determined SO2 concentrations are below the limit values for Turkey. | en_US |
dc.language.iso | en | en_US |
dc.publisher | PAMUKKALE UNIV | en_US |
dc.relation.ispartof | PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Air pollution; Hydrogen peroxide method; Sulfur dioxide; West-Gaeke | en_US |
dc.subject | method | en_US |
dc.title | Investigation of the applicability of West-Gaeke and hydrogen peroxide methods for sulfur dioxide analysis | en_US |
dc.title.alternative | Kükürt dioksit analizi için West-Gaeke ve hidrojen peroksit yöntemlerinin uygulanabilirliğinin araştırılması | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 24 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 522 | - |
dc.identifier.startpage | 522 | en_US |
dc.identifier.endpage | 526 | en_US |
dc.authorid | 0000-0001-7310-3906 | - |
dc.identifier.doi | 10.5505/pajes.2017.40221 | - |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.trdizinid | 305439 | en_US |
dc.identifier.wos | WOS:000436191100023 | en_US |
dc.owner | Pamukkale University | - |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
item.openairetype | Article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
crisitem.author.dept | 10.01. Environmental Engineering | - |
Appears in Collections: | Mühendislik Fakültesi Koleksiyonu TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
f907d9a9-5b4c-4e8f-80f2-113030fdb375.pdf | 806.76 kB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
68
checked on Aug 24, 2024
Download(s)
24
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.