Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/30487
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pekel, Gökhan. | - |
dc.contributor.author | Taşçı, Murat. | - |
dc.contributor.author | Bahar, A. | - |
dc.contributor.author | Pekel, E. | - |
dc.contributor.author | Çetin, E.N. | - |
dc.contributor.author | Martin, Ç. | - |
dc.contributor.author | Çobankara, V. | - |
dc.date.accessioned | 2020-06-08T12:13:45Z | |
dc.date.available | 2020-06-08T12:13:45Z | |
dc.date.issued | 2019 | - |
dc.identifier.issn | 0004-2749 | - |
dc.identifier.uri | https://hdl.handle.net/11499/30487 | - |
dc.identifier.uri | https://doi.org/10.5935/0004-2749.20190054 | - |
dc.description.abstract | Purpose: We aimed to compare the thickness of anterior sclera, corneal layers, and pre-ocular tear film between patients with primary Sjögren's syndrome and healthy individuals. Methods: Fifty-one patients with primary Sjögren's syndrome and 41 healthy control participants were recruited in this cross-sectional and comparative study. The thickness of the pre-ocular tear film, corneal epithelium, Bowman's layer, stroma, Descemet's membrane, and endothelium were measured on the corneal apex. Anterior scleral thickness was measured at distances of 1 mm and 3 mm from the limbus. The anterior segment module of spectral-domain optical coherence tomography was used to measure thicknesses of pre-ocular tear film, corneal layers, and anterior sclera. Results: Tear film thickness, Schirmer's test, and tear break up time values were significantly lower in the Sjögren's disease group than in the healthy controls (p < 0.05). The thickness measurements of corneal layers and sclera were similar between the groups. Tear film thickness was moderately correlated with the Schirmer's test results (r = 0.34, p = 0.001), but there was no correlation between the Schirmer's test results and tear break up time (r = 0.18, p = 0.09). Conclusions: Pre-ocular tear film, as measured by anterior segment optical coherence tomography, was thinner in patients with primary Sjögren's syndrome than in the healthy controls. The thicknesses of corneal layers and anterior sclera were similar between the groups. © 2019, Conselho Brasileiro De Oftalmologia. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Conselho Brasileiro De Oftalmologia | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Anterior eye segment | en_US |
dc.subject | Comparative study | en_US |
dc.subject | Sclera | en_US |
dc.subject | Sjögren-Larsson syndrome | en_US |
dc.subject | Tomography, optical coherence | en_US |
dc.subject | adult | en_US |
dc.subject | aged | en_US |
dc.subject | case control study | en_US |
dc.subject | cornea | en_US |
dc.subject | cross-sectional study | en_US |
dc.subject | diagnostic imaging | en_US |
dc.subject | female | en_US |
dc.subject | human | en_US |
dc.subject | lacrimal fluid | en_US |
dc.subject | male | en_US |
dc.subject | middle aged | en_US |
dc.subject | optical coherence tomography | en_US |
dc.subject | pathology | en_US |
dc.subject | pathophysiology | en_US |
dc.subject | physiology | en_US |
dc.subject | procedures | en_US |
dc.subject | reference value | en_US |
dc.subject | sclera | en_US |
dc.subject | Sjoegren syndrome | en_US |
dc.subject | Adult | en_US |
dc.subject | Aged | en_US |
dc.subject | Case-Control Studies | en_US |
dc.subject | Cornea | en_US |
dc.subject | Cross-Sectional Studies | en_US |
dc.subject | Female | en_US |
dc.subject | Humans | en_US |
dc.subject | Male | en_US |
dc.subject | Middle Aged | en_US |
dc.subject | Reference Values | en_US |
dc.subject | Sjogren's Syndrome | en_US |
dc.subject | Tears | en_US |
dc.subject | Tomography, Optical Coherence | en_US |
dc.title | Evaluation of corneal layers and anterior sclera in patients with primary Sjögren's syndrome | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 82 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 270 | |
dc.identifier.startpage | 270 | en_US |
dc.identifier.endpage | 274 | en_US |
dc.authorid | 0000-0002-4635-5179 | - |
dc.identifier.doi | 10.5935/0004-2749.20190054 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 30970120 | en_US |
dc.identifier.scopus | 2-s2.0-85071702960 | en_US |
dc.identifier.wos | WOS:000481653000003 | en_US |
dc.identifier.scopusquality | Q3 | - |
dc.owner | Pamukkale University | - |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
crisitem.author.dept | 14.01. Surgical Medicine | - |
crisitem.author.dept | 14.02. Internal Medicine | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
0004-2749-abo-20190054.pdf | 251.11 kB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
2
checked on Oct 13, 2024
WEB OF SCIENCETM
Citations
2
checked on Oct 31, 2024
Page view(s)
38
checked on Aug 24, 2024
Download(s)
14
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.