Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/30503
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yücens, Mehmet | - |
dc.contributor.author | Alemdaroğlu, K.B. | - |
dc.contributor.author | Özmeriç, A. | - |
dc.contributor.author | İltar, S. | - |
dc.contributor.author | Yildirim, A.Ö. | - |
dc.contributor.author | Aydoğan, N.H. | - |
dc.date.accessioned | 2020-06-08T12:13:56Z | - |
dc.date.available | 2020-06-08T12:13:56Z | - |
dc.date.issued | 2019 | - |
dc.identifier.issn | 1300-0144 | - |
dc.identifier.uri | https://hdl.handle.net/11499/30503 | - |
dc.identifier.uri | https://doi.org/10.3906/sag-1806-72 | - |
dc.description.abstract | Background/aim: The aim of this study is to compare the stability and implant stresses of suprapectineal plate with infrapectineal plate in three subconfigurations of the screw types. Materials and methods: The stabilities of different fixation methods were compared by finite element analysis on six models. Three infrapectineal and three suprapectineal models each with locked, unlocked, or combined screws were employed. Three-dimensional finite element stress analysis was performed by using isotropic materials with a load of 2.3 kN applied at standing positions. Motion at the fracture line was measured on four different points located on the pubic and iliac sides of the fracture line. Results: Infrapectineal plate fixation with unlocked screws was found to be the most stable fixation method with 0.006 mm displacement of fragments in all axes at standing positions. The suprapectineal unlocked method was found to be the most unstable in standing positions with maximum displacement values of 0.46 mm vertical shear movement in the x-axis, –0.14 mm displacement in the y-axis, and –0.33 mm lateral shear in the z-axis. Conclusion: The infrapectineal unlocked plate supplies the most stable fixation with the least implant stress, contrary to the suprapectineal unlocked plate, which has the lowest stability and highest implant stresses. © TUBİTAK. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Turkiye Klinikleri Journal of Medical Sciences | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Acetabular fracture | en_US |
dc.subject | Anterior column | en_US |
dc.subject | Finite eleme | en_US |
dc.subject | Fixation | en_US |
dc.subject | Infrapectineal | en_US |
dc.subject | Suprapectineal | en_US |
dc.subject | acetabulum fracture | en_US |
dc.subject | arm fracture | en_US |
dc.subject | Article | en_US |
dc.subject | biomechanics | en_US |
dc.subject | bone stress | en_US |
dc.subject | comparative study | en_US |
dc.subject | cortical bone | en_US |
dc.subject | finite element analysis | en_US |
dc.subject | human | en_US |
dc.subject | iliac bone | en_US |
dc.subject | infrapectineal fixation | en_US |
dc.subject | joint stability | en_US |
dc.subject | plate fixation | en_US |
dc.subject | pubic bone | en_US |
dc.subject | shear strength | en_US |
dc.subject | standing | en_US |
dc.subject | suprapectineal fixation | en_US |
dc.subject | three dimensional imaging | en_US |
dc.subject | acetabulum | en_US |
dc.subject | adult | en_US |
dc.subject | anatomy and histology | en_US |
dc.subject | bone screw | en_US |
dc.subject | devices | en_US |
dc.subject | fracture | en_US |
dc.subject | male | en_US |
dc.subject | osteosynthesis | en_US |
dc.subject | pathology | en_US |
dc.subject | physiology | en_US |
dc.subject | procedures | en_US |
dc.subject | visible human project | en_US |
dc.subject | Acetabulum | en_US |
dc.subject | Adult | en_US |
dc.subject | Biomechanical Phenomena | en_US |
dc.subject | Bone Screws | en_US |
dc.subject | Finite Element Analysis | en_US |
dc.subject | Fracture Fixation, Internal | en_US |
dc.subject | Fractures, Bone | en_US |
dc.subject | Humans | en_US |
dc.subject | Male | en_US |
dc.subject | Visible Human Projects | en_US |
dc.title | A comparative biomechanical analysis of suprapectineal and infrapectineal fixation oacetabular anterior column fracture by finite element modeling | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 49 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 442 | - |
dc.identifier.startpage | 442 | en_US |
dc.identifier.endpage | 448 | en_US |
dc.identifier.doi | 10.3906/sag-1806-72 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 30761832 | en_US |
dc.identifier.scopus | 2-s2.0-85061594998 | en_US |
dc.identifier.trdizinid | 335992 | en_US |
dc.identifier.wos | WOS:000458367000062 | en_US |
dc.identifier.scopusquality | Q3 | - |
dc.owner | Pamukkale University | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.fulltext | With Fulltext | - |
item.languageiso639-1 | en | - |
item.grantfulltext | open | - |
crisitem.author.dept | 14.01. Surgical Medicine | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
sag-49-1-63-1806-72.pdf | 2.7 MB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
7
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
6
checked on Nov 21, 2024
Page view(s)
48
checked on Aug 24, 2024
Download(s)
14
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.