Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/36654
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUfuk, Furkan-
dc.contributor.authorDemirci, Mahmut-
dc.contributor.authorUğurlu, Erhan-
dc.contributor.authorÇetin, Nazlı-
dc.contributor.authorYiğit, Nilüfer-
dc.contributor.authorSarı, Tuğba-
dc.date.accessioned2021-02-02T09:17:04Z-
dc.date.available2021-02-02T09:17:04Z-
dc.date.issued2020-
dc.identifier.issn1305-3612-
dc.identifier.issn1305-3825-
dc.identifier.urihttps://hdl.handle.net/11499/36654-
dc.identifier.urihttps://doi.org/10.5152/dir.2020.20281-
dc.description.abstractPURPOSE: We aimed to assess the severity of coronavirus disease 2019 (COVID-19) pneumonia on computed tomography (CT) using quantitative (QCT) and semiquantitative (SCT) assessments and compare with the clinical findings. METHODS: Two observers independently examined the CT images of COVID-19 patients, and the SCT severity score was calculated. The SCT score was calculated as the sum of values ranging from 0 to 4, according to the volumetric rate of involvement for each lung lobe. In quantitative assessment, total lung volume (TLV) was automatically calculated from CT density values between -200 and -950 HU. Besides, healthy lung volume (HLV) was calculated from voxels between -800 and -950 HU. The QCT score was calculated with the following formula: (TLV - HLV / TLV) ×100. All patients were clinically divided into four groups: mild, common, severe, and critical. Interobserver agreement for SCT assessment was investigated using the Cohen's Kappa statistics (κ). Pearson's correlation coefficient was used for the relationship between continuous data. The diagnostic accuracy of SCT and QCT in the differentiation of clinically limited (mild, common) and extensive (severe, critical) disease was investigated using ROC analysis. RESULTS: Seventy-six patients with a diagnosis of COVID-19 were included. There was good agreement between the two observers in the SCT evaluation of pulmonary disease severity (κ = 0.796; 95% CI, 0.751-0.841). A significant correlation was found between QCT and SCT scores (P < 0.001, r = 0.661). Both QCT and SCT scores showed a significant correlation with clinical severity score (P < 0.001, r = 0.620 and P = 0.004, r = 0.529, respectively). The ROC analysis revealed the AUC of QCT and SCT for differentiation of limited and extensive disease as 0.873 (95% CI, 0.774-0.972) and 0.816 (95% CI, 0.673-0.959), respectively. CONCLUSION: The QCT assessment is an objective method in the evaluation of COVID-19 severity and is more successful than semiquantitative CT assessment to discriminate extensive from limited disease.en_US
dc.language.isoenen_US
dc.relation.ispartofDiagnostic and interventional radiology (Ankara, Turkey)en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEvaluation of disease severity with quantitative chest CT in COVID-19 patients.en_US
dc.typeArticleen_US
dc.authorid0000-0002-8614-5387-
dc.authorid0000-0001-8201-9618-
dc.authorid0000-00015402-6925-
dc.authorid0000-0003-3204-2371-
dc.identifier.doi10.5152/dir.2020.20281-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid33044173en_US
dc.identifier.scopus2-s2.0-85099285560en_US
dc.identifier.trdizinid456587en_US
dc.identifier.wosWOS:000629039700002en_US
dc.identifier.scopusqualityQ2-
dc.ownerPamukkale University-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextopen-
crisitem.author.dept14.02. Internal Medicine-
crisitem.author.dept14.02. Internal Medicine-
crisitem.author.dept14.02. Internal Medicine-
crisitem.author.dept14.02. Internal Medicine-
crisitem.author.dept14.02. Internal Medicine-
crisitem.author.dept14.02. Internal Medicine-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
20281.pdf1.28 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

15
checked on Nov 16, 2024

WEB OF SCIENCETM
Citations

12
checked on Nov 16, 2024

Page view(s)

76
checked on Aug 24, 2024

Download(s)

32
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.