Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/37246
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBahar, A.-
dc.contributor.authorPekel, Gökhan-
dc.date.accessioned2021-02-02T09:24:41Z
dc.date.available2021-02-02T09:24:41Z
dc.date.issued2020-
dc.identifier.issn1536-4798-
dc.identifier.urihttps://hdl.handle.net/11499/37246-
dc.identifier.urihttps://doi.org/10.1097/ICO.0000000000002212-
dc.description.abstractPURPOSE: To investigate the effects of the light intensity of the recording room where eye examinations are conducted on the evaluation of lens and corneal clarity. METHOD: This cross-sectional and comparative study used 63 eyes of 32 participants. Corneal and lenticular optical densitometries, pachymetry, corneal volume, anterior segment volume, and anterior chamber depth measurements were taken with the Scheimpflug imaging system when the lights in the recording room were on (80 lux) and off (3 lux). The results were statistically compared. RESULTS: The mean lens density when the lights were on was 13.61 ± 2.03, whereas that when the lights were off was 8.48 ± 1.48 (P < 0.001). Similarly, the mean corneal density when the lights were on was 15.87 ± 1.36, whereas that when the lights were off was 11.13 ± 0.90 (P < 0.001). The pachymetry, corneal volume, anterior segment volume, and anterior chamber depth measurements did not differ under the different light conditions. CONCLUSIONS: The densitometry values increased with an increase in light intensity. This study revealed that the lens and corneal densitometry evaluations were significantly affected by the lighting in the recording room.en_US
dc.language.isoenen_US
dc.publisherNLM (Medline)en_US
dc.relation.ispartofCorneaen_US
dc.relation.ispartofUluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectadolescenten_US
dc.subjectadulten_US
dc.subjectageden_US
dc.subjectbiometryen_US
dc.subjectcomparative studyen_US
dc.subjectcorneaen_US
dc.subjectcross-sectional studyen_US
dc.subjectdensitometryen_US
dc.subjectdevicesen_US
dc.subjectdiagnostic imagingen_US
dc.subjectfemaleen_US
dc.subjecthumanen_US
dc.subjectilluminationen_US
dc.subjectlensen_US
dc.subjectmaleen_US
dc.subjectmiddle ageden_US
dc.subjectnormal humanen_US
dc.subjectphysical examinationen_US
dc.subjectphysiologyen_US
dc.subjecttomographyen_US
dc.subjectyoung adulten_US
dc.subjectAdolescenten_US
dc.subjectAdulten_US
dc.subjectAgeden_US
dc.subjectBiometryen_US
dc.subjectCorneaen_US
dc.subjectCross-Sectional Studiesen_US
dc.subjectDensitometryen_US
dc.subjectDiagnostic Imagingen_US
dc.subjectFemaleen_US
dc.subjectHealthy Volunteersen_US
dc.subjectHumansen_US
dc.subjectLens, Crystallineen_US
dc.subjectLightingen_US
dc.subjectMaleen_US
dc.subjectMiddle Ageden_US
dc.subjectPhysical Examinationen_US
dc.subjectTomographyen_US
dc.subjectYoung Adulten_US
dc.titleHow Does Light Intensity of the Recording Room Affect the Evaluation of Lens and Corneal Clarity by Scheimpflug Tomography?en_US
dc.typeArticleen_US
dc.relation.journalCorneaen_US
dc.relation.journalUluslararası Hakemli Dergien_US
dc.identifier.volume39en_US
dc.identifier.issue2en_US
dc.identifier.startpage137en_US
dc.identifier.endpage139en_US
dc.authorid0000-0002-9509-8500-
dc.identifier.doi10.1097/ICO.0000000000002212-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid31714403en_US
dc.identifier.scopus2-s2.0-85077402699en_US
dc.identifier.wosWOS:000524347000007en_US
dc.identifier.scopusqualityQ1-
dc.ownerPamukkale University-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.grantfulltextnone-
item.cerifentitytypePublications-
crisitem.author.dept14.01. Surgical Medicine-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

8
checked on Nov 23, 2024

WEB OF SCIENCETM
Citations

9
checked on Nov 24, 2024

Page view(s)

40
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.