Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/37333
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Akman, Alp | - |
dc.contributor.author | Demirkan, Ahmet Fahir | - |
dc.contributor.author | Akkoyunlu, Nuran A. Sabir | - |
dc.date.accessioned | 2021-02-02T09:25:15Z | - |
dc.date.available | 2021-02-02T09:25:15Z | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 2687-4784 | - |
dc.identifier.uri | https://hdl.handle.net/11499/37333 | - |
dc.identifier.uri | https://doi.org/10.5606/ehc.2020.65258 | - |
dc.description.abstract | Objectives: This study aims to investigate if geometrical modelling in addition to three-dimensional (3D) modelling will standardize models and allow performing mathematical calculations easily for the compatibility of femoral implant curvature. Patients and methods: The study included 50 subjects (27 males, 23 females; mean age 55 years; range, 21 to 84 years). The femoral shaft intramedullary cavity was resembled into a chord of the ring cyclide, where the rotational radius was centered at its smallest radius. A 3D evaluation of the left femoral computed tomography data of the subjects was used to investigate the population parameters. The fitting was defined as being between the anterior and posterior border radii in the sagittal plane. Results: The best fitting radius of implants was in between 90 to 99 cm in 72% of subjects in our sample. These radii values were lower than the mean intramedullary and cortical centerline radii which had only 62% and 50% fittings, respectively, among our population sample. The bowing radii and the smallest intramedullary width increased with the femoral length. These values were not affected by gender. Conclusion: This modelling may have value for understanding femoral shaft intramedullary cavity geometry and may be a good tool to assess implant fitting. © 2020 Turkish Joint Diseases Foundation. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Turkish Joint Diseases Foundation | en_US |
dc.relation.ispartof | Joint Diseases and Related Surgery | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Anthropometry | en_US |
dc.subject | Bowing of the femur | en_US |
dc.subject | Humans | en_US |
dc.subject | Ring cyclide | en_US |
dc.subject | anatomic model | en_US |
dc.subject | diagnostic imaging | en_US |
dc.subject | female | en_US |
dc.subject | femur | en_US |
dc.subject | human | en_US |
dc.subject | male | en_US |
dc.subject | middle aged | en_US |
dc.subject | procedures | en_US |
dc.subject | radius | en_US |
dc.subject | surgery | en_US |
dc.subject | three-dimensional imaging | en_US |
dc.subject | x-ray computed tomography | en_US |
dc.subject | Female | en_US |
dc.subject | Femur | en_US |
dc.subject | Imaging, Three-Dimensional | en_US |
dc.subject | Male | en_US |
dc.subject | Middle Aged | en_US |
dc.subject | Models, Anatomic | en_US |
dc.subject | Radius | en_US |
dc.subject | Tomography, X-Ray Computed | en_US |
dc.title | Three-dimensional geometrical modelling of the femoral intramedullary cavity using ring cyclide model | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 31 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 14 | - |
dc.identifier.startpage | 14 | en_US |
dc.identifier.endpage | 19 | en_US |
dc.authorid | 0000-0001-7830-1979 | - |
dc.authorid | 0000-0002-1393-7068 | - |
dc.authorid | 0000-0002-3412-7355 | - |
dc.identifier.doi | 10.5606/ehc.2020.65258 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 32160488 | en_US |
dc.identifier.scopus | 2-s2.0-85090766129 | en_US |
dc.identifier.trdizinid | 367713 | en_US |
dc.identifier.wos | WOS:000521139200004 | en_US |
dc.identifier.scopusquality | - | - |
dc.owner | Pamukkale University | - |
item.grantfulltext | open | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
crisitem.author.dept | 14.01. Surgical Medicine | - |
crisitem.author.dept | 14.01. Surgical Medicine | - |
crisitem.author.dept | 14.02. Internal Medicine | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
2020-31-1-014-019-eng.pdf | 580.98 kB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
56
checked on Aug 24, 2024
Download(s)
24
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.