Title: | Prematüre bebeklerde bant sıyırmaya bağlı cilt hasarının önlenmesi: Randomize kontrollü çalışma | Other Titles: | Prevention of skin damage caused by tape stripping in premature infants: Randomized controlled trial | Authors: | Özsayın, Asuman | Advisors: | Çetinkaya, Bengü | Keywords: | prematüre bebek hidrokolloid yapıştırıcılar epidermis premature infant hydrocolloid adhesives epidermis |
Publisher: | Pamukkale Üniversitesi Sağlık Bilimleri Enstitüsü | Abstract: | Araştırma yenidoğan yoğun bakım ünitesinde yapılan randomize kontrollü çalışmadır. Ekipman sabitlemek için kullanılan yapıştırma yöntemleri karşılaştırılmıştır.Yöntemler; koruyucu hidrokolloid örtü + ipek bant / silikon bant / ipek bant + silikon bazlı çözücü spreydir. İpek bant + silikon bazlı çözücü sprey klinikte rutin olarak kullanılan yöntemdir. Araştırmaya 32 – 36 gestasyon haftasında 75 adet prematüre bebek alınmıştır. Yöntemler orogastrik sonda sabitlemede uygulanmış, bant ciltte 24 saat kalmıştır. Bant yapıştırma öncesi cilt durumu değerlendirilmiş, 24 saat sonra bant çıkarılmış ve cilt durumu yeniden değerlendirilmiştir. Prematüre Bebekleri Tanıtıcı Bilgi Formu ve Yenidoğan Cilt Durum Değerlendirmesi ölçeği araçları kullanılmıştır. Veriler SPSS 22 paket programıyla analiz edilmiştir. Araştırma için etik kuruldan ve kurumdan izin alınmıştır. Uygulama sonu cilt durum skorları ortalamaları koruyucu hidrokolloid örtü grubunda 3,2±0,5, silikon bant grubunda 3,12±0,44 ve ipek bant + silikon bazlı çözücü sprey grubunda 6,12±1,24 bulunmuştur. Hidrokolloid örtü + ipek bant grubunda doğum ağırlığı ile uygulama sonu cilt durum skorları arasında istatistiksel olarak anlamlı, negatif yönde, orta düzeyde ilişki saptanmıştır (r=-,432, p<0,05). Koruyucu hidrokolloid örtünün klinikte kullanımı önerilir; ancak doğum ağırlığı azaldıkça cilt durum skorunu orta düzeyde arttırdığı görüldüğü için çok düşük doğum ağırlıklı bebeklerde dikkatle kullanılması önerilmektedir. Silikon bant grubu en iyi uygulama sonu cilt durum skoruna sahiptir; fakat yapışma gücünün zayıf olduğu görüldüğü için hayati risk taşımayan ekipmanlarda değerlendirilmesi önerilmektedir. İpek bant + silikon bazlı çözücü sprey cilt durum skorunun arttırmıştır, bu nedenle alternatif yöntemlerinin kullanılması uygundur. The study is a randomized controlled study conducted in neonatal intensive care units. The bonding methods used for fixing were compared. Methods; protective hydrocolloid dressing + silk tape / silicone tape / silk tape + silicone-based solvent spray. Silk tape + silicone-based solvent spray is the method routinely used in the clinic. 75 premature infants between 32 and 36 weeks of gestation were included in the study. The methods were applied in orogastric tube fixation, the tape remained on the skin for 24 hours. Before applying the tape, the skin condition was evaluated, the tape was removed after 24 hours and the skin condition was re-evaluated. Premature Infants Introductory Information Form and Neonatal Skin Condition Score tools were used. The data were analyzed with the SPSS 22 package program. Permission was obtained from the ethics committee and institution for the research. The mean skin condition scores at the end of the application were 3.2 ± 0.5 in the protective hydrocolloid dressing group, 3.12 ± 0.44 in the silicone band group, and 6.12 ± 1.24 in the silk tape + silicone-based solvent spray group. In the hydrocolloid dressing group, a statistically significant, negative, moderate correlation was found between birth weight and post-application skin condition scores (r =-,432, p <0.05). It has been observed that the use of protective hydrocolloid dressing increases the skin condition score moderately as the birth weight decreases, therefore it is recommended to be used with caution in very low birth weight infants. The silicone tape group has the best postapplication skin condition score, but; it is recommended to use it in equipment that does not have life-threatening risks, as it appears to have weak adhesion. Silk tape + silicone-based solvent spray has increased the skin condition score, so it is convenient to use alternative methods. |
URI: | https://hdl.handle.net/11499/38592 |
Appears in Collections: | Tez Koleksiyonu |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Asuman Özsayın.pdf | 4.28 MB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
836
checked on Aug 24, 2024
Download(s)
592
checked on Aug 24, 2024
Google ScholarTM
Check
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.