Title: | Detecting Intralabyrinthine Pressure Increase by Postural Manipulation with Wideband Tympanometry and Distortion Product Otoacoustic Emissions | Authors: | Yucel, E Ardic, FN Tumkaya, F Kara, CO Topuz, B |
Keywords: | Inner ear; resonance frequency analysis; tympanometry; otoacoustic emission; intracranial pressure |
Publisher: | GALENOS YAYINCILIK | Abstract: | Objective: Intracranial pressure increase is known to affect inner ear pressure through the cochlear and vestibular aqueducts. This finding forms a good model for inner ear pressure studies. Standard techniques used to detect this pressure increase are neither reliable nor easily repeatable or cheap. Studies with immitancemetry and otoacoustic emissions have been giving hopeful results. This study aims to confirm the results in the literature with wideband tympanometry and add a new parameter of otoacoustic emissions to inner ear pressure testing. Methods: Wideband tympanometry (WBT) and distortion product otoacoustic emissions (DPOAE) tests were applied to 40 healthy participants in sitting, supine, and Trendelenburg positions. DPOAE were measured under ambient or peak pressure. Resonance frequency, tympanic peak pressure, 1000, 1500, 2000, 3000, 4000, and 6000 Hz frequencies in DPOAE were measured. Results: The increase in the tympanic peak pressure and the decrease in resonance frequency (RF) due to position change were found statistically significant (p<0.01). Signal noise ratio (SNR) decrease at 1 kHz frequency and SNR increase at 2, 3, 6 kHz in the normal protocol, SNR decrease at 1 kHz in the pressurized protocol were found statistically significant (p<0.01). Conclusion: RF in WBT and 1 kHz DPOAE SNR parameters were found useful in supporting the diagnosis in pathologies that increase intracranial pressure and inner ear pressure. Future research may ease their widespread use in clinical practice as they are non-invasive and rapidly applicable. |
URI: | https://hdl.handle.net/11499/39108 https://doi.org/10.5152/tao.2020.5530 |
ISSN: | 2667-7466 |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Tıp Fakültesi Koleksiyonu TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
tao-58-203-En.pdf | 150.24 kB | Adobe PDF | View/Open |
CORE Recommender
WEB OF SCIENCETM
Citations
3
checked on Nov 21, 2024
Page view(s)
68
checked on Aug 24, 2024
Download(s)
22
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.