Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/4245
Title: Intraobserver repeatability of automated versus adjusted optical coherence tomography measurements in patients with neovascular age-related macular degeneration
Authors: Tatlıpınar, Sinan.
Shah, S.M.
Campochiaro, P.A.
Nguyen, Q.D.
Keywords: Neovascular age-related macular degeneration
Optical coherence tomography
Repeatability, automated vs. adjusted optical coherence tomography measurements
aged
article
automation
bootstrapping
clinical article
computer program
controlled study
correlation analysis
female
human
male
neovascularization (pathology)
optical coherence tomography
retina fovea
retina macula age related degeneration
retina macula lutea
statistical significance
Aged
Choroidal Neovascularization
Female
Humans
Macular Degeneration
Male
Observer Variation
Reproducibility of Results
Retina
Tomography, Optical Coherence
Abstract: Aim: To assess the intraobserver repeatability of automated versusadjusted optical coherence tomography (OCT) measurements in patients with neovascular age-related macular degeneration (NVAMD). Methods: Ten eyes with NVAMD from 10 consecutive patients underwent two OCT measurements within 5 days by a single operator. Automated and adjusted central 1-mm foveal thickness and automated and adjusted total macular volume were measured in each study eye. The term 'adjusted' refers to manually corrected values, in which the interface landmarks for measurements are selected by the operator using Stratus® scan profiling and custom software. Bland-Altman method and bootstrap comparison of intraclass correlations (ICCs) were used for repeatability analysis. Results: Bland-Altman comparison did not reveal any statistically significant difference in any parameter, when results at first and second examination were compared (p > 0.05), indicating that the repeated measurements are similar. Further analysis was conducted using the bootstrap comparison of ICCs. The difference between adjusted and automated foveal thickness ICCs (r = 0.945 and 0.635, respectively) was significant (p = 0.031), indicating higher repeatability for adjusted foveal thickness. The ICCs for adjusted and automated total macular volume (r = 0.873 and 0.863, respectively) showed no statistically significant difference (p = 0.881). Conclusion: The repeatability of adjusted retinal thickness measurements, in which the errors of retinal boundary detection by OCT analysis software is corrected by the operator using scan profiling, is found to be higher than that of automated ones in this small group of NVAMD patients when performed by a single experienced operator. Copyright © 2006 S. Karger AG.
URI: https://hdl.handle.net/11499/4245
https://doi.org/10.1159/000101923
ISSN: 0030-3755
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

SCOPUSTM   
Citations

7
checked on Jun 29, 2024

WEB OF SCIENCETM
Citations

7
checked on Jul 10, 2024

Page view(s)

28
checked on May 27, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.