Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/4402
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Acar, P. | - |
dc.contributor.author | Özel, A.D. | - |
dc.contributor.author | Canel, E. | - |
dc.contributor.author | Ocak, Ü. | - |
dc.contributor.author | Şentürk, H.B. | - |
dc.contributor.author | Gök, Yaçar. | - |
dc.contributor.author | Kiliç, E. | - |
dc.date.accessioned | 2019-08-16T11:33:54Z | |
dc.date.available | 2019-08-16T11:33:54Z | |
dc.date.issued | 2007 | - |
dc.identifier.issn | 0792-1241 | - |
dc.identifier.uri | https://hdl.handle.net/11499/4402 | - |
dc.identifier.uri | https://doi.org/10.1515/MGMC.2007.30.2-3.117 | - |
dc.description.abstract | The construction, performance, and application of mercury (II) - selective PVC membrane electrodes based on 7,8-dinitro-4,11-dioxa-22,32-dithia-1,14- diazapentacyclo [12.10.10.0 5.10 .10 16.21 .0 26.31 ] tetratriaconta-5,7,9,16,18,20,26,28,30-nonane (cryptand I) and 7-nitro-4,11-dioxa-22,32-dithia-1,14-diazapentacyclo [12.10.10.0 5.10 .10 16.21 .0 26.31 ] tetratriaconta-5,7,9,16, 18,20,26,28,30-nonane (cryptand II) as novel cryptand derivatives are reported. An optimum membrane composition of 2 % ionophore, 68.3 % plasticizer, 29.7 % poly(vinyl chloride) (PVC), and 75 % mol lipophilic anionic additive with respect to the ionophore is found for both of the electrodes. The influences of plasticizer, internal filling solution and pH on the potentiometric response of the electrodes were investigated. The electrodes exhibit twice-Nernstian response for Hg (II) ion over a wide concentration range within solutions of pH 2.0 - 3.0. The proposed electrodes show good selectivity for mercury (II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions and especially silver(I) ions. The electrodes have a response time of about 15-20 s and they can be used for at least 1 month without any divergence. The practical applications of the proposed cryptand I and II based mercury (II) - selective electrodes were observed by using them as indicator electrodes in potentiometric titrations of mercury (II) ions with EDTA. Hg (II) ISE based on cryptand II appeared to be more suitable than Hg (II) ISE based on cryptand I for potentiometric titrations. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Walter de Gruyter GmbH | en_US |
dc.relation.ispartof | Main Group Metal Chemistry | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.title | Mercury (II) - Selective PVC membrane electrodes based on novel cryptand derivatives | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 30 | en_US |
dc.identifier.issue | 2-3 | en_US |
dc.identifier.startpage | 117 | |
dc.identifier.startpage | 117 | en_US |
dc.identifier.endpage | 133 | en_US |
dc.identifier.doi | 10.1515/MGMC.2007.30.2-3.117 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopus | 2-s2.0-39449087656 | en_US |
dc.identifier.wos | WOS:000253693300007 | en_US |
dc.identifier.scopusquality | Q2 | - |
dc.owner | Pamukkale University | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.openairetype | Article | - |
Appears in Collections: | Fen-Edebiyat Fakültesi Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
2
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
2
checked on Nov 21, 2024
Page view(s)
16
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.