Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/4472
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Başer, Sevin | - |
dc.contributor.author | Kiter, G. | - |
dc.contributor.author | Kavas, M. | - |
dc.contributor.author | Moray, A. | - |
dc.contributor.author | Ozkurt, S. | - |
dc.contributor.author | Akdag, B. | - |
dc.contributor.author | Evyapan, F. | - |
dc.date.accessioned | 2019-08-16T11:34:18Z | - |
dc.date.available | 2019-08-16T11:34:18Z | - |
dc.date.issued | 2006 | - |
dc.identifier.issn | 0741-238X | - |
dc.identifier.uri | https://hdl.handle.net/11499/4472 | - |
dc.identifier.uri | https://doi.org/10.1007/BF02850227 | - |
dc.description.abstract | Oxygen therapy, which is ordered frequently for patients with chronic pulmonary disease, remains a cornerstone of modern medical practice. This study was conducted to compare the efficiency and comfort of a binasal cannula versus a face mask during oxygen therapy. Sixty hypoxemic patients participated in this randomized controlled study. While each patient was hypoxemic, arterial blood gas analysis was performed before oxygen supplementation was begun. Arterial oxygen saturation was continuously monitored during oxygen therapy with a face mask or a binasal cannula. Subjects were allowed to return to their oxygen saturation level in room air before the device for oxygen treatment was changed. The same procedure was then repeated with the other device. Patient comfort was evaluated through the use of a questionnaire that was completed after each treatment period. The mean age±standard deviation was 62±13 y. No statistically significant difference was noted in oxygen saturation levels achieved with the 2 devices. The binasal cannula reached target oxygen levels (P=.007) more quickly than the face mask. The binasal cannula was reported to be significantly more comfortable (P=.0001), and had significantly fewer reports of dyspnea and restlessness, and was less of a nuisance (P=.019, P=.0001, and P=.0001, respectively). The binasal cannula was preferred for oxygen therapy by 71% of study patients. Although the efficiency of the 2 devices did not differ remarkably, the binasal cannula was regarded as a more comfortable and time-saving device for delivery of oxygen therapy to hypoxic patients. ©2006 Health Communications Inc. | en_US |
dc.language.iso | en | en_US |
dc.relation.ispartof | Advances in Therapy | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Chronic pulmonary disease | en_US |
dc.subject | Face mask | en_US |
dc.subject | Nasal cannula | en_US |
dc.subject | Oxygen therapy | en_US |
dc.subject | adult | en_US |
dc.subject | aged | en_US |
dc.subject | arterial gas | en_US |
dc.subject | article | en_US |
dc.subject | asthma | en_US |
dc.subject | blood gas analysis | en_US |
dc.subject | cannula | en_US |
dc.subject | chronic lung disease | en_US |
dc.subject | chronic obstructive lung disease | en_US |
dc.subject | clinical article | en_US |
dc.subject | clinical trial | en_US |
dc.subject | comparative study | en_US |
dc.subject | controlled clinical trial | en_US |
dc.subject | controlled study | en_US |
dc.subject | device | en_US |
dc.subject | dyspnea | en_US |
dc.subject | face mask | en_US |
dc.subject | female | en_US |
dc.subject | human | en_US |
dc.subject | hypoxemia | en_US |
dc.subject | interstitial lung disease | en_US |
dc.subject | lung cancer | en_US |
dc.subject | lung embolism | en_US |
dc.subject | male | en_US |
dc.subject | medical practice | en_US |
dc.subject | oxygen saturation | en_US |
dc.subject | oxygen supply | en_US |
dc.subject | oxygen therapy | en_US |
dc.subject | questionnaire | en_US |
dc.subject | randomized controlled trial | en_US |
dc.subject | restlessness | en_US |
dc.subject | sleep apnea syndrome | en_US |
dc.subject | Adult | en_US |
dc.subject | Aged | en_US |
dc.subject | Aged, 80 and over | en_US |
dc.subject | Anoxemia | en_US |
dc.subject | Chronic Disease | en_US |
dc.subject | Female | en_US |
dc.subject | Humans | en_US |
dc.subject | Intubation | en_US |
dc.subject | Lung Diseases | en_US |
dc.subject | Male | en_US |
dc.subject | Masks | en_US |
dc.subject | Middle Aged | en_US |
dc.subject | Oxygen Inhalation Therapy | en_US |
dc.subject | Patient Satisfaction | en_US |
dc.title | Binasal cannula versus face mask for oxygen therapy in patients with chronic pulmonary disease | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 23 | en_US |
dc.identifier.issue | 6 | en_US |
dc.identifier.startpage | 1068 | - |
dc.identifier.startpage | 1068 | en_US |
dc.identifier.endpage | 1074 | en_US |
dc.identifier.doi | 10.1007/BF02850227 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 17276974 | en_US |
dc.identifier.scopus | 2-s2.0-33847364830 | en_US |
dc.identifier.wos | WOS:000244518100024 | en_US |
dc.identifier.scopusquality | Q2 | - |
dc.owner | Pamukkale_University | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | 14.02. Internal Medicine | - |
crisitem.author.dept | 14.03. Basic Medical Sciences | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |