Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/44956
Title: | Comparison of stability of seven biochemistry analytes in serum separator and plasma tubes | Authors: | Avcı, Esin Demir, Süleyman Nar, Rukiye Akpınar, Kadriye |
Abstract: | Objectives: The aim of the present study was to compare the stability of 7 routine analytes using a BD Vacutainer Barricorplasma blood collection tube, a BD Vacutainer SST (Becton Dickinson and Company, Franklin Lakes, NJ, USA) anda Vacusera SST ((Disera A.S., Izmir, Turkey).Methods: Five mL blood samples from 60 volunteers were collected into the 3 tubes. Glucose, urea, creatinine, lactatedehydrogenase (LD), sodium (Na), chloride (Cl) and potassium (K) levels were analyzed at 0, 4, 8, and 12 hours on aCobas 8000 analyzer ((F. Hoffmann-La Roche Ltd., Basel, Switzerland). Bias and bias% results were calculated and comparedto clinically acceptable limits (CAL).Results: Intraclass correlation results revealed excellent agreement in the 7 chemistry analytes between the 3 tubes(0.863-1.000). The CAL for Cl, creatinine, glucose, K, LD, Na and urea are 3 mmol/L, 10%, 0.3 mg/dL, 10%, 0.5 mmol/L,20%, 3 mmol/L and 2mg/dl, respectively. At the 12th hour, there was a difference observed in glucose between Barricor-SST and Barricor-Vacusera SST were 10.06 mg/dL (11.38 %) and 11.14 mg/dL (-12.76%). Analytical coefficient (CV)of variation results for glucose, LD, creatinine, urea, Na, K, and Cl were 3.22%, 5.80%, 5.28%, 3.90%, 2.00%, 1.95%, and1.37% respectively.Conclusion: Although the stability of all 7 analytes was within the CAL during a 12-hour period, clinically different resultswere obtained. In terms of stability evaluation, the use of plasma might be preferable in clinical laboratories. Theroutine chemistry analytes studied were within the clinically acceptable range in both plasma and serum specimens,but validation and estimation of reference intervals for plasma tubes are needed. | URI: | https://hdl.handle.net/11499/44956 https://doi.org/10.14744/ijmb.2019.74745 |
ISSN: | 2587-2362 2618-642X |
Appears in Collections: | Tıp Fakültesi Koleksiyonu TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
a5eed8e7-5cab-4775-8dd1-7ce063b21058.pdf | 130.08 kB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
84
checked on Aug 24, 2024
Download(s)
46
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.