Title: | Spectrophotometric determination of paracetamol in urine with tetrahydroxycalix[4]arene as a coupling reagent and preconcentration with Triton X-114 using cloud point extraction | Authors: | Filik, H. Şener, İzzet Cekiç, S.D. Kiliç, E. Apak, R. |
Keywords: | Calix[4]arene Cloud point extraction P-aminophenol Paracetamol determination Spectrophotometry Urine 4 aminophenol calixarene dye oxidizing agent paracetamol surfactant tetrahydroxycalix[4]arene triton x 100 triton x 114 unclassified drug absorption article calibration centrifugation drug determination drug isolation extraction human human experiment hydrolysis micelle normal human room temperature spectrophotometry stoichiometry ultraviolet radiation Acetaminophen Aminophenols Drugs, Chinese Herbal Indicators and Reagents Polyethylene Glycols Surface-Active Agents Temperature |
Abstract: | In the present paper, conventional spectrophotometry in conjunction with cloud point extraction-preconcentration were investigated as alternative methods for paracetamol (PCT) assay in urine samples. Cloud point extraction (CPE) was employed for the preconcentration of p-aminophenol (PAP) prior to spectrophotometric determination using the non-ionic surfactant Triton X-114 (TX-114) as an extractant. The developed methods were based on acidic hydrolysis of PCT to PAP, which reacted at room temperature with 25,26,27,28- tetrahydroxycalix[ 4]arene (CAL4) in the presence of an oxidant (KIO 4) to form an blue colored product. The PAP-CAL4 blue dye formed was subsequently entrapped in the surfactant micelles of Triton X-114. Cloud point phase separation with the aid of Triton X-114 induced by addition of Na 2SO4 solution was performed at room temperature as an advantage over other CPE assays requiring elevated temperatures. The 580 nm-absorbance maximum of the formed product was shifted bathochromically to 590 nm with CPE. The working range of 1.5-12 µg ml-1 achieved by conventional spectrophotometry was reduced down to 0.14-1.5 µg ml -1 with cloud point extraction, which was lower than those of most literature flow-through assays that also suffer from nonspecific absorption in the UV region. By preconcentrating 10 ml sample solution, a detection limit as low as 40.0 ng ml-1 was obtained after a single-step extraction, achieving a preconcentration factor of 10. The stoichiometric composition of the dye was found to be 1:4 (PAP:CAL4). The impact of a number of parameters such as concentrations of CAL4, KIO4, Triton X-100 (TX-100), and TX-114, extraction temperature, time periods for incubation and centrifugation, and sample volume were investigated in detail. The determination of PAP in the presence of paracetamol in micellar systems under these conditions is limited. The established procedures were successfully adopted for the determination of PCT in urine samples. Since the drug is rapidly absorbed and excreted largely in urine and its high doses have been associated with lethal hepatic necrosis and renal failure, development of a rapid, sensitive and selective assay of PCT is of vital importance for fast urinary screening and antidote administration before applying more sophisticated, but costly and laborious hyphenated instrumental techniques of HPLC-SPE-NMR-MS. © 2006 Pharmaceutical Society of Japan. | URI: | https://hdl.handle.net/11499/4586 https://doi.org/10.1248/cpb.54.891 |
ISSN: | 0009-2363 |
Appears in Collections: | Fen-Edebiyat Fakültesi Koleksiyonu PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
54_891.pdf | 111.98 kB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
34
checked on Dec 14, 2024
WEB OF SCIENCETM
Citations
35
checked on Dec 19, 2024
Page view(s)
50
checked on Aug 24, 2024
Download(s)
28
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.