Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/46605
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kamal, Muhammet | - |
dc.contributor.author | Inel, Mehmet | - |
dc.date.accessioned | 2023-01-09T21:15:29Z | - |
dc.date.available | 2023-01-09T21:15:29Z | - |
dc.date.issued | 2022 | - |
dc.identifier.issn | 0141-0296 | - |
dc.identifier.issn | 1873-7323 | - |
dc.identifier.uri | https://doi.org/10.1016/j.engstruct.2021.113610 | - |
dc.identifier.uri | https://hdl.handle.net/11499/46605 | - |
dc.description.abstract | This study aims to investigate the determination of seismic separation gap of adjacent low and mid-rise reinforced concrete (RC) buildings with no structural irregularity using nonlinear time history analysis. The low and mid-rise RC buildings were reflected using 3, 4, 5, 6, 7, 8, 9 and 10-story buildings designed per 2018 Turkish Building Earthquake Code (TBEC-2018). Beam and column elements are modeled as nonlinear frame elements with lumped plasticity by defining plastic hinges at both ends of beams and columns. The adjacent threedimensional (3D) building models are connected to each other by link elements at the floor levels. 1232 nonlinear dynamic (time history) analyses were performed using 56 different building pairs and 11 different earthquake record pairs (22 records) compatible with TBEC-2018 to obtain the required seismic gap distances. The distances necessary to avoid pounding obtained from the analyses were compared with the minimum seismic gap requirements of the current earthquake codes, provisions (Eurocode-8, ASCE 7-16 and TBEC-2018) and several proposed methods (ABS, SRSS and DDC) in the literature. The outcomes indicate that the ASCE 7-16 and EC-8 significantly overestimate the required seismic gap distances for the buildings with similar dynamic characteristics while they provide reasonable estimates for the buildings with significantly different dynamic characteristics. However, the TBEC-2018 requirements are insufficient for the neighboring building period ratios greater than 1.25. Although both the ASCE 7-16 and EC-8 requirements are acceptable for the design of new buildings as being on safe side, they are not useful for the evaluation of existing buildings. Two different simple approaches were proposed to estimate the required seismic gap distances between neighboring buildings. The first approach requires linear static analysis of the buildings subjected to the reduced seismic design forces while the second simplified approach does not need any analysis. The proposed equations in this study are simple and useful for the evaluation of existing low and mid-rise RC buildings with no structural irregularity. Besides, their estimates are acceptable for the design purposes. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Sci Ltd | en_US |
dc.relation.ispartof | Engineering Structures | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Low and mid-rise RC buildings | en_US |
dc.subject | Adjacent buildings | en_US |
dc.subject | Nonlinear time history analysis | en_US |
dc.subject | Seismic pounding | en_US |
dc.subject | Separation distance | en_US |
dc.subject | Simplified approaches | en_US |
dc.subject | Response Vectors | en_US |
dc.subject | Pounding Damage | en_US |
dc.subject | Performance | en_US |
dc.subject | Envelopes | en_US |
dc.subject | Model | en_US |
dc.subject | Risk | en_US |
dc.title | Simplified approaches for estimation of required seismic separation distance between adjacent reinforced concrete buildings | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 252 | en_US |
dc.identifier.doi | 10.1016/j.engstruct.2021.113610 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorscopusid | 57208641862 | - |
dc.authorscopusid | 55894025500 | - |
dc.identifier.scopus | 2-s2.0-85120316580 | en_US |
dc.identifier.wos | WOS:000776087000001 | en_US |
dc.identifier.scopusquality | Q1 | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | Article | - |
item.cerifentitytype | Publications | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | 10.02. Civil Engineering | - |
crisitem.author.dept | 10.02. Civil Engineering | - |
Appears in Collections: | Mühendislik Fakültesi Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
15
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
14
checked on Nov 21, 2024
Page view(s)
50
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.