Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/46739
Title: Seismic behavior of mid-rise reinforced concrete adjacent buildings considering soil-structure interaction
Authors: Kamal, Muhammet
Inel, Mehmet
Cayci, Bayram Tanik
Keywords: Seismic pounding
Structure-soil-structure interaction
Mid-rise RC buildings
Adjacent buildings
Nonlinear time history analysis
Seismic behavior
Height Multistory Buildings
Dynamic-Response
Soft Soils
Model
Parameters
Damages
Publisher: Elsevier
Abstract: This study aims to investigate the effects of structure-soil-structure interaction (SSSI), soilstructure interaction (SSI) and fixed-base (FB) assumptions on seismic behavior in mid-rise reinforced concrete (RC) buildings located on soft soil. Three-dimensional (3D) high ductility RC frames 5-, 8-, 10-, 13-, and 15-storey buildings are modeled as a fully nonlinear frame element. Five different structural cases were created: SSSI models with and without pounding, FB models with and without pounding, and SSI models. In the scope of this study, direct finite element modeling of 3D inelastic soil volume was considered. A detailed investigation has been carried out considering 65 different model combinations to reflect SSSI, SSI and FB modelling approaches. As a result, total of 1365 analyses using 21 different ground motion records, the lateral displacement demands and displacement profiles of the buildings were examined and presented. It is found that the seismic behavior of adjacent buildings located on soft soils is different from the fixed-base assumption. The buildings should not be evaluated alone, as neighboring buildings on soft soils affect each other. Neighboring building and soil effects should be considered for buildings up to 8-storey even no collision occurs. For buildings with higher than 8-storey, it may be reasonable to consider SSI only with neglecting neighboring building effects if there is no collision. If the seismic gap distance between adjacent buildings is insufficient and seismic pounding potential exists, neighboring building effects with soil-structure interaction should be taken into account independent from building height.
URI: https://doi.org/10.1016/j.jobe.2022.104296
https://hdl.handle.net/11499/46739
ISSN: 2352-7102
Appears in Collections:Mühendislik Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

SCOPUSTM   
Citations

26
checked on Nov 16, 2024

WEB OF SCIENCETM
Citations

22
checked on Nov 21, 2024

Page view(s)

84
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.