Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/46739
Title: | Seismic behavior of mid-rise reinforced concrete adjacent buildings considering soil-structure interaction | Authors: | Kamal, Muhammet Inel, Mehmet Cayci, Bayram Tanik |
Keywords: | Seismic pounding Structure-soil-structure interaction Mid-rise RC buildings Adjacent buildings Nonlinear time history analysis Seismic behavior Height Multistory Buildings Dynamic-Response Soft Soils Model Parameters Damages |
Publisher: | Elsevier | Abstract: | This study aims to investigate the effects of structure-soil-structure interaction (SSSI), soilstructure interaction (SSI) and fixed-base (FB) assumptions on seismic behavior in mid-rise reinforced concrete (RC) buildings located on soft soil. Three-dimensional (3D) high ductility RC frames 5-, 8-, 10-, 13-, and 15-storey buildings are modeled as a fully nonlinear frame element. Five different structural cases were created: SSSI models with and without pounding, FB models with and without pounding, and SSI models. In the scope of this study, direct finite element modeling of 3D inelastic soil volume was considered. A detailed investigation has been carried out considering 65 different model combinations to reflect SSSI, SSI and FB modelling approaches. As a result, total of 1365 analyses using 21 different ground motion records, the lateral displacement demands and displacement profiles of the buildings were examined and presented. It is found that the seismic behavior of adjacent buildings located on soft soils is different from the fixed-base assumption. The buildings should not be evaluated alone, as neighboring buildings on soft soils affect each other. Neighboring building and soil effects should be considered for buildings up to 8-storey even no collision occurs. For buildings with higher than 8-storey, it may be reasonable to consider SSI only with neglecting neighboring building effects if there is no collision. If the seismic gap distance between adjacent buildings is insufficient and seismic pounding potential exists, neighboring building effects with soil-structure interaction should be taken into account independent from building height. | URI: | https://doi.org/10.1016/j.jobe.2022.104296 https://hdl.handle.net/11499/46739 |
ISSN: | 2352-7102 |
Appears in Collections: | Mühendislik Fakültesi Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
26
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
22
checked on Nov 21, 2024
Page view(s)
84
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.