Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/48507
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKarasu, Uğur-
dc.contributor.authorÇobankara, Veli-
dc.contributor.authorKaymaz, Serdar-
dc.contributor.authorAlkan, Hakan-
dc.date.accessioned2023-01-09T21:38:05Z-
dc.date.available2023-01-09T21:38:05Z-
dc.date.issued2021-
dc.identifier.issn2651-2653-
dc.identifier.issn2651-2661-
dc.identifier.urihttps://doi.org/10.4274/raed.galenos.2021.21931-
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/508125-
dc.identifier.urihttp://acikerisim.pau.edu.tr:8080/xmlui/handle/11499/48507-
dc.description.abstractObjective: Depressive symptoms harm the quality of life, with a higher prevalence in patients with rheumatological diseases. The Patient Health Questionnaire-9 (PHQ-9) used for depression evaluation in patients with systemic sclerosis (SSc) has been validated in Turkish. However, the Turkish version of PHQ-8, a shorter form of PHQ-9, has not been validated. This study aimed to evaluate the reliability and validity of PHQ-8 in Turkish patients with SSc. Methods: Permission was obtained from the authors who developed the original scale. The testing procedure for translation and cultural adaptation was carried out according to the following steps: preparation, forward translation, reconciliation, back-translation/backtranslation review, harmonization, finalization, and proofreading. Patients’ demographic parameters, comorbidities, education levels, organ involvement, Health Assessment Questionnaire (HAQ), Scleroderma Health Assessment Questionnaire (SHAQ), Short form36 (SF-36), and Multidimensional Assessment of Fatigue (MAF) results were recorded. Construct validity, test-retest reliability, and internal consistency were evaluated in 43 patients with SSc. Results: Despite some linguistic changes, the questionnaire had satisfactory content validity. There were moderate-to-strong correlations between the Turkish version of PHQ-8 and SHAQ consisting of visual analog scale (rs=0.6 to 0.7) and HAQ disability (rs=0.5), the subscales of SF-36 (rs=0.6 to 0.8), and MAF (rs=0.7). The internal consistency (Cronbach’s alpha) of the questionnaire was 0.98, with corrected item-to-total correlations of >0.40, and an intraclass correlation coefficient of 0.947 for the total score (Intraclass correlation coefficient=0.947, 95% confidence interval, 0.817-0.985). Conclusion: The Turkish version of PHQ-8 could be used to evaluate patients with SSc with satisfactory construct validity and sufficient reliability.en_US
dc.language.isoenen_US
dc.relation.ispartofUlusal Romatoloji Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleValidity and reliability of the Turkish version of the Patient Health Questionnaire-8 for patients with systemic sclerosisen_US
dc.typeArticleen_US
dc.identifier.volume13en_US
dc.identifier.issue2en_US
dc.identifier.startpage66en_US
dc.identifier.endpage72en_US
dc.departmentPAUen_US
dc.identifier.doi10.4274/raed.galenos.2021.21931-
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinid508125en_US
item.openairetypeArticle-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.cerifentitytypePublications-
crisitem.author.dept14.02. Internal Medicine-
crisitem.author.dept14.02. Internal Medicine-
crisitem.author.dept14.02. Internal Medicine-
crisitem.author.dept14.02. Internal Medicine-
Appears in Collections:Tıp Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection
Files in This Item:
File SizeFormat 
document (9).pdf147.99 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

100
checked on Aug 24, 2024

Download(s)

48
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.