Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/49169
Title: | Kurşun, demir ve kadmiyumun chromosorb 105 kolonuyla deriştirilmesi ve atomik absorpsiyon spektrometresi ile tayinleri | Other Titles: | Determination of lead | Authors: | Elçi, Aydan | Advisors: | Bağ, Hüseyin | Keywords: | Kimya Chemistry Kurşun demir kadmiyum Chromosorb- 105 kolonu Zenginleştirme Atomik absorpsiyon spektrometrisi Lead iron cadmium Chromosorb- 105 column Preconcentration Atomic absorption spectrometry |
Publisher: | Pamukkale Üniversitesi | Abstract: | V Bu çalışmada, alevli ve grafit fırınlı atomik absorpsiyon spektrometresi ile bazı su örneklerindeki Pb, Fe ve Cd tayini için kolon tekniğini esas alan bir zenginleştirme yöntemi geliştirildi. Tamponlanmış örnek çözeltilerindeki analit iyonları dietilditiyokarbamat kompleksleri halinde Chromosorb 105 reçinesi ile dolgulu kolonda tutuldu. Tutunan kompleksler aseton veya 0,01 M EDTA çözeltisi ile elue edildi. Yöntemin verimliliğini etkileyen pH, reçine miktarı, ligand miktarı, örnek hacmi, akış hızı ve yabancı iyon etkisi gibi bazı parametreler değerlendirildi. Optimum çalışma koşullan altmda Pb, Fe ve Cd için geri kazanma verimleri sırasıyla % 100+4, % 91+6 ve % 90±3 olarak bulundu. Bağıl standart sapmalar % 6'dan küçüktür. Bağıl hata % 5'den küçüktür. Pb, Fe ve Cd için gözlenebilme sınırlan sırasıyla 0,36, 0,15 ve 0,18 ug/mL olarak bulundu. Geliştirilen yöntem, Çandarlı ve Aliağa körfezlerinden alman deniz suyu ve laboratuvanmızdan alman çeşme suyuna uygulandı. Anahtar kelimeler: Kurşun, demir, kadmiyum; Chromosorb- 105 kolonu; Zenginleştirme; Atomik absorpsiyon spektrometrisi VI In this study, preconcentration method based on a column technique was developed for determination of Pb, Fe and Cd in some water samples by flame or graphite furnace atomic absorption spectrometry. The analyte ions as their dietilditiyokarbamate complexes were retained on a column filled with chromosorb 105 resin from buffered sample solutions. The retained complexes were eluted with acetone or 0,01 M EDTA solution. Several parameters governing the efficiency of the method were evaluated including pH, resin amount, ligand amount, sample volume, flow rates and divers ion effects. The recoveries of Pb, Fe and Cd under the optimum working conditions were found to be as 100±4 %, 97+6 % and 90±3 %, respectively. The relative standard deviations were less than 6%. The relative error was less than 5 %. The detection limits of lead, iron and cadmium were found to be 0,36, 0,15 and 0,18 ug/mL, respectively. The developed method was applied to sea water samples taken from Çandarlı and Aliağa Gulfs, and tap water sample taken from our laboratory. Keywords: Lead, iron, cadmium; Chromosorb- 105 column; Preconcentration; Atomic absorption spectrometry |
Description: | Bu tezin, veri tabanı üzerinden yayınlanma izni bulunmamaktadır. Yayınlanma izni olmayan tezlerin basılı kopyalarına Üniversite kütüphaneniz aracılığıyla (TÜBESS üzerinden) erişebilirsiniz. | URI: | https://hdl.handle.net/11499/49169 |
Appears in Collections: | Tez Koleksiyonu |
Show full item record
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.