Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/50733
Title: Removal of amoxicillin via chromatographic monolithic columns: comparison between batch and continuous fixed bed
Authors: Ağlamaz, Mustafa Deniz
Şarkaya, Koray
Türkmen, Deniz
Uçar, Mustafa
Denizli, Adil
Keywords: Monolithic column
hydrophobic interaction
liquid chromatography
amoxicillin
adsorption
Abstract: This study preŞented a hydrophobic interaction-based poly(HEMA-MATrp) monolithic chromatographic column (MCC) to remove amoxicillin from aqueous solutions. In addition to their porous structure, monolithic-filled columns offer superior properties without loss of performance, which is one of the points that make them unique. The specific surface area of the monolithic column synthesized by the bulk polymerization of 2-hydroxyethyl methacrylate and N-Methacryloyl-L-tryptophan. Also, poly(HEMA- MATrp) MCC has been characterized via FTIR, SEM, and elemental analysis. According to BET analysis, the specific surface area of the poly(HEMA-MATrp) monolithic chromatographic column (MCC) is 14.2 mg/g. The adsorption and desorption of amoxicillin in an aqueous solution were investigated comparatively in both continuous fixed bed and batch adsorption. The highest adsorption value of amoxicillin was determined at pH 7 in the preŞence of PBS as 62.11 mg/g. The appropriate adsorption isotherm for the adsorption of amoxicillin was Langmuir, and the reaction kinetics was pseudo-second-order. No significant loss was observed for the adsorption capacity of poly(HEMA-MATrp) MCC after the 5 cycles of adsorption-desorption studies. Also, the loss for the adsorption capacity of the monolithic column is just %5.2 after 6-month storage, proving the reusability and storability of the monolithic column.
URI: https://doi.org/10.55730/1300-0527.3520
https://search.trdizin.gov.tr/yayin/detay/1158660
https://hdl.handle.net/11499/50733
ISSN: 1300-0527
1303-6130
Appears in Collections:Fen-Edebiyat Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
Removal of amoxicillin via chromatographic monolithic columns_ co.pdf1.13 MBAdobe PDFView/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

1
checked on Dec 21, 2024

WEB OF SCIENCETM
Citations

1
checked on Dec 20, 2024

Page view(s)

64
checked on Aug 24, 2024

Download(s)

12
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.