Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/5098
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKaplan, H.-
dc.contributor.authorYilmaz, S.-
dc.contributor.authorBinici, H.-
dc.contributor.authorYazar, E.-
dc.contributor.authorÇetinkaya, N.-
dc.date.accessioned2019-08-16T11:41:21Z-
dc.date.available2019-08-16T11:41:21Z-
dc.date.issued2004-
dc.identifier.issn1350-6307-
dc.identifier.urihttps://hdl.handle.net/11499/5098-
dc.identifier.urihttps://doi.org/10.1016/j.engfailanal.2003.08.005-
dc.description.abstractOn 01.05.2003 an earthquake of magnitude 6.4 occurred in Eastern Anatolia causing damage to hundreds of reinforced concrete (RC) and masonry buildings. Inspections carried out in the disaster area have given an idea about damage types and quality of concrete used in these buildings. The most interesting point is that lots of school buildings constructed within the last 5-6 years were damaged heavily. Poor concrete quality and poor reinforcement detailing caused damage in these structures. Although many are thought to be constructed according to renewed earthquake code in 1997, it is observed that in construction of collapsed or damaged buildings, code requirements and technical issues are ignored. Some tests after the earthquake showed that the quality of concrete in the damaged buildings is poorer than the one assumed in building projects. In this paper, reasons why the buildings were damaged in the 01.05.2003 earthquake in Bingöl, Turkey are given. Some suggestions are made to prevent such disasters in the future. © 2003 Elsevier Ltd. All rights reserved.en_US
dc.language.isoenen_US
dc.relation.ispartofEngineering Failure Analysisen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBuilding failuresen_US
dc.subjectConcreteen_US
dc.subjectEarthquake damageen_US
dc.subjectReinforcementen_US
dc.subjectConcrete constructionen_US
dc.subjectDisaster preventionen_US
dc.subjectInspectionen_US
dc.subjectMasonry constructionen_US
dc.subjectQuality controlen_US
dc.subjectSchool buildingsen_US
dc.subjectDamageen_US
dc.subjectEastern Anatoliaen_US
dc.subjectMasonry buildingsen_US
dc.subjectEarthquakesen_US
dc.subjectearthquakeen_US
dc.titleMay 1, 2003 Turkey - Bingöl earthquake: Damage in reinforced concrete structuresen_US
dc.typeArticleen_US
dc.identifier.volume11en_US
dc.identifier.issue3en_US
dc.identifier.startpage279-
dc.identifier.startpage279en_US
dc.identifier.endpage291en_US
dc.identifier.doi10.1016/j.engfailanal.2003.08.005-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-18444379077en_US
dc.identifier.wosWOS:000220514000001en_US
dc.identifier.scopusqualityQ2-
dc.ownerPamukkale_University-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairetypeArticle-
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
crisitem.author.dept10.02. Civil Engineering-
crisitem.author.dept10.02. Civil Engineering-
Appears in Collections:Mühendislik Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

62
checked on Dec 14, 2024

WEB OF SCIENCETM
Citations

57
checked on Dec 20, 2024

Page view(s)

70
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.