Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/51195
Full metadata record
DC FieldValueLanguage
dc.contributor.authorŞimşek, F. Selçuk-
dc.contributor.authorÇakmak, Muharrem-
dc.contributor.authorKuşlu, Duygu-
dc.contributor.authorBalcı, Tansel A.-
dc.contributor.authorİn, Erdal-
dc.contributor.authorÖzercan, İbrahim H.-
dc.contributor.authorNarin, Yavuz-
dc.date.accessioned2023-06-13T19:12:44Z-
dc.date.available2023-06-13T19:12:44Z-
dc.date.issued2023-
dc.identifier.issn1734-1922-
dc.identifier.issn1896-9151-
dc.identifier.urihttps://doi.org/10.5114/aoms/111529-
dc.identifier.urihttps://hdl.handle.net/11499/51195-
dc.description.abstractIntroduction: There is no consensus about the standardized uptake value maximum (SUVmax) cut-off value to characterize pleural thickening world-wide. Sometimes, this causes unnecessary invasive diagnostic procedures. Our first aim is to determine a cut-off value for SUVmax. Secondly, we try to answer the following question: If we use this cut-off value together with morphological parameters, can we differentiate benign thickening from ma-lignant pleural mesothelioma (MPM) more accurately? Materialand methods:Thirty-seven patientswho underwent 2-deoxy-2-fluoro-D-glucose ([18F]FDG) positron emission tomography/computed tomography (PET/CT) before pleural biopsy were included the study. All of patients had histopathologically proven primary pleural disease. Their [18F]FDG-PET/CT im-aging reports were re-assessed. If a patient's SUVmax or size of the thickening was not mentioned in the report, we calculated it with their [18F]FDG-PET/CT. Results: Age, pleural effusion, size, and SUVmax were found to have a relation-ship with MPM. We found the size > 14 mm, and SUVmax > 4.0 as cut-off values for MPM. The sensitivity, specificity, positive predictive value (PPV), and nega-tive predictive value (NPV) for size > 14 mm were found to be 86.4%, 85.2%, 82.6%, 88.5%, respectively. For SUVmax > 4.0, sensitivity, specificity, PPV, NPV were 90.9%, 87.0%, 85.1%, 92.2%, respectively. Conclusions: If a patient has SUVmax> 4.0 and/or size > 14 mm, the risk of MPM is high. These patients should undergo biopsy. If a patient's SUVmax < 4.0, size < 14 mm and does not have pleural effusion, he/she has low risk for MPM. These patients can undergo the follow-up. If a patient's SUVmax < 4, size < 14, and has pleural effusion the MPM risk is approximately 4%. These patients can undergo biopsy/cytology/follow-up. Novel studies are needed for these patients.en_US
dc.language.isoenen_US
dc.publisherTermedia Publishing House Ltden_US
dc.relation.ispartofArchives of Medical Scienceen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectmesotheliomaen_US
dc.subjectcut-off valueen_US
dc.subjectpleural thickeningen_US
dc.subject18F-FDG-PETen_US
dc.subjectMesotheliomaen_US
dc.subjectDiagnosisen_US
dc.titleHow can we use positron emission tomography/ computed tomography more accurately for characterization of asbestos-related pleural thickening?en_US
dc.typeArticleen_US
dc.identifier.volume19en_US
dc.identifier.issue2en_US
dc.identifier.startpage385en_US
dc.identifier.endpage391en_US
dc.departmentPamukkale Universityen_US
dc.identifier.doi10.5114/aoms/111529-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid56903959400-
dc.authorscopusid35147662600-
dc.authorscopusid56904287200-
dc.authorscopusid8922657100-
dc.authorscopusid21742842200-
dc.authorscopusid7004374166-
dc.authorscopusid6601970889-
dc.identifier.pmid37034512en_US
dc.identifier.scopus2-s2.0-85152245821en_US
dc.identifier.wosWOS:000980693500014en_US
dc.institutionauthor-
dc.identifier.scopusqualityQ2-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.grantfulltextopen-
item.openairetypeArticle-
crisitem.author.dept14.02. Internal Medicine-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
pdf-111529-88402.pdf91.18 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

52
checked on Aug 24, 2024

Download(s)

12
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.