Title: | Evaluation of the performance of the pre-analytical phase of the testing process in medical laboratory accreditation | Authors: | Emekli, Dilek İren Aslan, Diler Zorbozan, Nergiz |
Abstract: | Introduction: For the accreditation of a medical laboratory, it is necessary to evaluate the quality indicators (QI) used to evaluate pre-analytical process performance and establish an infrastructure to prevent errors arising from outside the laboratory. We aimed to present the quality indicators to prove the pre-analytical process performance of a medical (clinical) laboratory that has a large workforce prepared for medical laboratory accreditation. Methods: The sample rejection criteria were defined for the pre-analytical process. QIs, which are the requirements of the ISO15189 standard, was determined. QIs were estimated both as percentages and process Sigma levels. Pareto charts presented the distribution of errors. Results: QI values calculated as “%” and “Sigma” levels consistently demonstrated performances. According to 80% cumulated percentages, the Pareto charts rankings were “haemolysed,” “coagulated,” “barcode error,” and “insufficient” samples. In addition, when Pareto charts were evaluated, it was seen that the first 2 reasons in the 6-month period were “hemolysis” and “clotted samples” in all months. Still, the third most common reason was found to vary between “barcode error” and “insufficient” samples. Discussion and Conclusion: Because of the consistency between % and sigma values, QIs can be presented with one of these in showing laboratory pre-analytical processes. However, sigma values give a more general view, and performance can be easily monitored between months. Pareto charts help illustrate error distribution and provide information for continuous improvement in laboratory-related healthcare. | URI: | https://doi.org/10.54307/NWMJ.2022.43534 https://search.trdizin.gov.tr/yayin/detay/1175279 https://hdl.handle.net/11499/51495 |
ISSN: | 2757-7724 |
Appears in Collections: | Tıp Fakültesi Koleksiyonu TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
NWMJ-43534-ORIGINAL_RESEARCH-IREN_EMEKLI.pdf | 787.04 kB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
54
checked on Aug 24, 2024
Download(s)
6
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.