dc.contributor.authorSemiz, Ender.-
dc.contributor.authorErmiş, C.-
dc.contributor.authorYalçinkaya, S.-
dc.contributor.authorSancaktar, O.-
dc.contributor.authorDeger, N.-
dc.date.accessioned2019-08-16T11:42:49Z
dc.date.available2019-08-16T11:42:49Z
dc.date.issued2003-
dc.identifier.issn0021-4868-
dc.identifier.urihttps://hdl.handle.net/11499/5195-
dc.identifier.urihttps://doi.org/10.1536/jhj.44.889-
dc.description.abstractThe implantation of heparin-coated stents was reported to be well tolerated, but there are conflicting results about acute in-hospital complications, (sub)acute thrombosis rates, and long-term follow-up compared to uncoated stents. We compared the angiographic and clinical results after coronary placement of two stent models: the heparin-coated premounted Jostent and the uncoated premounted NIR stent. Of 710 patients revascularized, a total of 426 patients received Jostent (n = 230) or NIR stent (n = 196) implantation. The primary end points were acute or subacute thrombosis, urgent CABG, AMI or death, while the secondary end points were the comparison of the restenosis rates of the stents at the 6th month and of the functional angina classification of the stent groups at the 1st, 6th and 12th months. There were no significant differences between the Jostent and NIR stent groups regarding angiographic and procedural success. Acute thrombosis rates in the Jostent and NIR stent groups were similar while no subacute thrombosis was observed in either group. The major adverse cardiac event rates of the groups also did not differ. Angiographic restenosis occurred in 17% of the Jostent group and 16% of the NIR stent group (NS). The combined clinical and angiographic restenosis rate was also similar between the Jo and NIR groups (19% and 18%, respectively). Comparison of functional angina classes at the 1st, 6th and 12th months revealed no significant difference between the study groups. In conclusion, when compared with implantation of an uncoated premounted NIR stent, implantation of a heparin-coated premounted Jostent does not provide any more benefit with respect to initial efficacy, sub(acute) thrombosis and 6-month restenosis rates and 12-month clinical outcomes. Copyright © 2004 by the Japanese Heart Journal.en_US
dc.language.isoenen_US
dc.relation.ispartofJapanese Heart Journalen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCoatingen_US
dc.subjectCoronary diseaseen_US
dc.subjectCoronary stentsen_US
dc.subjectHeparinen_US
dc.subjectRestenosisen_US
dc.subjectheparinen_US
dc.subjectbiomaterialen_US
dc.subjectacute heart infarctionen_US
dc.subjectadulten_US
dc.subjectageden_US
dc.subjectarticleen_US
dc.subjectcardiovascular surgeryen_US
dc.subjectcomparative studyen_US
dc.subjectcontrolled studyen_US
dc.subjectcoronary artery bypass graften_US
dc.subjectcoronary artery diseaseen_US
dc.subjectcoronary stenten_US
dc.subjectemergency treatmenten_US
dc.subjectfemaleen_US
dc.subjecthumanen_US
dc.subjectlong term careen_US
dc.subjectmajor clinical studyen_US
dc.subjectmaleen_US
dc.subjectmaterial coatingen_US
dc.subjectmortalityen_US
dc.subjectoutcomes researchen_US
dc.subjectpriority journalen_US
dc.subjectrestenosisen_US
dc.subjectthrombosisen_US
dc.subjectcoronary artery thrombosisen_US
dc.subjectfollow upen_US
dc.subjectheart muscle revascularizationen_US
dc.subjectmiddle ageden_US
dc.subjectretrospective studyen_US
dc.subjectstenten_US
dc.subjectAgeden_US
dc.subjectCoated Materials, Biocompatibleen_US
dc.subjectCoronary Diseaseen_US
dc.subjectCoronary Restenosisen_US
dc.subjectCoronary Thrombosisen_US
dc.subjectFemaleen_US
dc.subjectFollow-Up Studiesen_US
dc.subjectHumansen_US
dc.subjectMaleen_US
dc.subjectMiddle Ageden_US
dc.subjectMyocardial Revascularizationen_US
dc.subjectRetrospective Studiesen_US
dc.subjectStentsen_US
dc.titleComparison of initial efficacy and long-term follow-up of heparin-coated Jostent with conventional NIR stenten_US
dc.typeArticleen_US
dc.identifier.volume44en_US
dc.identifier.issue6en_US
dc.identifier.startpage889
dc.identifier.startpage889en_US
dc.identifier.endpage898en_US
dc.identifier.doi10.1536/jhj.44.889-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid14711184en_US
dc.identifier.scopus2-s2.0-1242308949en_US
dc.identifier.wosWOS:000226557100008en_US
dc.ownerPamukkale_University-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.grantfulltextopen-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
44_889.pdf79.93 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

8
checked on Nov 16, 2024

WEB OF SCIENCETM
Citations

6
checked on Nov 21, 2024

Page view(s)

26
checked on Aug 24, 2024

Download(s)

16
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.