Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/52056
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAkduman, Çiğdem-
dc.date.accessioned2023-08-22T18:49:10Z-
dc.date.available2023-08-22T18:49:10Z-
dc.date.issued2023-
dc.identifier.issn0021-8995-
dc.identifier.issn1097-4628-
dc.identifier.urihttps://hdl.handle.net/11499/52056-
dc.identifier.urihttps://doi.org/10.1002/app.54344-
dc.description.abstractThe fabrication of a high-performance PTFE membrane remains challenging and still under interest. Electrospinning is one of the possible fabrication methods for PTFE membranes. But, due to the high solvent resistance and the high melt viscosity, PTFE emulsion should be blended with a carrier polymer solution and then it can be electrospinned. In this study, PTFE membranes were produced with four different ratios of PVA and PEO polymers as carrier and then sintered at 380 degrees C, to left only PTFE nanofibers behind. Produced hydrophobic PTFE membranes' WCA values were between 120-132 degrees for PEO/PTFE nanofibers and 112-124 degrees for PVA/PTFE nanofibers. SEM images revealed that PEO/PTFE membranes preserved their fibrous structure better. After sintering, diameter of 7PEO/PTFE, 8PEO/PTFE, 9PEO/PTFE, and 10PEO/PTFE nanofibers were 612, 818, 822, and 923 nm, respectively. Only 30PVA/PTFE nanofibers showed some fiber structure after sintering with evenly distributed pores. PEO/PTFE membranes were thicker than commercial syringe filter membranes and PVA/PTFE membranes and was about 0.24 p.m. Although mean pore size measurements of both PEO/PTFE and PVA/PTFE membranes were 0.90 and 1.07 p.m, respectively and higher than commercial membranes, bacterial removal tests of PEO/PTFE membrane were promising and close to commercial syringe filter results with 1.3 3log CFU/mL.en_US
dc.language.isotren_US
dc.publisherWileyen_US
dc.relation.ispartofJournal of Applied Polymer Scienceen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectbacterial removalen_US
dc.subjectelectrospinningen_US
dc.subjectnanofibersen_US
dc.subjectpolytetrafluoroethyleneen_US
dc.subjectsyringe filtersen_US
dc.subjectPtfeen_US
dc.titlePreparation and comparison of electrospun PEO/PTFE and PVA/PTFE nanofiber membranes for syringe filtersen_US
dc.typeArticleen_US
dc.identifier.volume140en_US
dc.identifier.issue35en_US
dc.departmentPamukkale Universityen_US
dc.authoridAkduman, Cigdem/0000-0002-6379-6697-
dc.identifier.doi10.1002/app.54344-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid56024613800-
dc.authorwosidAkduman, Cigdem/A-7584-2014-
dc.identifier.scopus2-s2.0-85164199718en_US
dc.identifier.wosWOS:001022216600001en_US
dc.institutionauthor-
dc.identifier.scopusqualityQ2-
item.cerifentitytypePublications-
item.languageiso639-1tr-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.fulltextWith Fulltext-
item.openairetypeArticle-
crisitem.author.dept31.02. Textile, Clothing, Shoes and Leather-
Appears in Collections:Denizli Teknik Bilimler Meslek Yüksekokulu Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
J of Applied Polymer Sci - 2023 - Akduman.pdf12.38 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

6
checked on Jan 21, 2025

WEB OF SCIENCETM
Citations

5
checked on Jan 22, 2025

Page view(s)

62
checked on Jan 21, 2025

Download(s)

26
checked on Jan 21, 2025

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.