Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/52774
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bahar, Alperen | - |
dc.contributor.author | Kaya, Hüseyin | - |
dc.date.accessioned | 2023-10-27T07:05:58Z | - |
dc.date.available | 2023-10-27T07:05:58Z | - |
dc.date.issued | 2023 | - |
dc.identifier.issn | 1300-0659 | - |
dc.identifier.issn | 2147-2661 | - |
dc.identifier.uri | https://doi.org/10.4274/tjo.galenos.2022.42724 | - |
dc.identifier.uri | https://hdl.handle.net/11499/52774 | - |
dc.description.abstract | Objectives: To investigate the effects of pupil diameter on the evaluation of lens and corneal densitometry measured by Scheimpflug tomography. Materials and Methods: This cross-sectional and comparative study used the right eyes of 32 participants. Corneal and lenticular optical densitometries, corneal volume, anterior segment volume, and anterior chamber depth measurements were taken with the Scheimpflug imaging system when the pupils were mid-dilated and fully dilated. The results were statistically compared. Results: The mean lens density was 19.20 +/- 3.05 when the pupils were middilated (mean pupil diameter 2.98 +/- 0.89 mm) and 23.25 +/- 3.88 at full dilation (mean pupil diameter 5.01 +/- 0.92 mm) (p<0.001). The mean corneal density was 16.15 +/- 0.99 with mid-dilated pupils and 16.38 +/- 0.95 with fully dilated pupils (p=0.065). Anterior chamber depth and anterior segment volume measurements increased with larger pupil diameter (p<0.05). Conclusion: The lens densitometry values increased with an increase in pupil diameter. The corneal density measurements increased minimally but the differences were not statistically significant. This study revealed that lens densitometry was significantly affected by pupil diameter. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Galenos Publ House | en_US |
dc.relation.ispartof | Turk Oftalmoloji Dergisi-Turkish Journal of Ophthalmology | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Lens | en_US |
dc.subject | cornea | en_US |
dc.subject | densitometry | en_US |
dc.subject | light intensity | en_US |
dc.subject | pupil size | en_US |
dc.subject | Density | en_US |
dc.title | How Does Pupil Size Affect Lens and Corneal Densitometry Measured by Scheimpflug Tomography? | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 53 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 222 | en_US |
dc.identifier.endpage | 225 | en_US |
dc.department | Pamukkale University | en_US |
dc.identifier.doi | 10.4274/tjo.galenos.2022.42724 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorscopusid | 56699710100 | - |
dc.authorscopusid | 55838731300 | - |
dc.identifier.pmid | 37602578 | en_US |
dc.identifier.scopus | 2-s2.0-85168427747 | en_US |
dc.identifier.wos | WOS:001053176800005 | en_US |
dc.institutionauthor | … | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.fulltext | With Fulltext | - |
crisitem.author.dept | 14.01. Surgical Medicine | - |
crisitem.author.dept | 14.01. Surgical Medicine | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
How Does Pupil Size Affect Lens.pdf | 223.93 kB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
44
checked on Aug 24, 2024
Download(s)
52
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.