Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/5422
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSaracoglu, S.-
dc.contributor.authorSoylak, M.-
dc.contributor.authorElçi, Latif-
dc.date.accessioned2019-08-16T11:46:49Z
dc.date.available2019-08-16T11:46:49Z
dc.date.issued2002-
dc.identifier.issn0003-2719-
dc.identifier.urihttps://hdl.handle.net/11499/5422-
dc.identifier.urihttps://doi.org/10.1081/AL-120006727-
dc.description.abstractAn on-line solid phase extraction system has been established for flow injection flame atomic absorption spectrometric determination of chromium on Chromotrope 2R coated Amberlite XAD-1180 (2R-1180) resin. Some parameters such as pH, flow rates of sample and elution solution, matrix effects on the quantitative recoveries of chromium from the resin were examined. The detection limit (3?) was 2.59 µ/L for preconcentration at 6.5 mL/min. The method was applied for the determination of traces chromium in natural water samples with satisfactory results (relative standard deviations below 5%, recoveries >95%).en_US
dc.language.isoenen_US
dc.relation.ispartofAnalytical Lettersen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectChromotrope 2R Coated Amberlite XAD-1180 resinen_US
dc.subjectFlow injectionen_US
dc.subjectPreconcentrationen_US
dc.subjectSeparationen_US
dc.subjectSolid phase extractionen_US
dc.subjectchromiumen_US
dc.subjectdrinking wateren_US
dc.subjectpolacrilinen_US
dc.subjectresinen_US
dc.subjectsea wateren_US
dc.subjectanalytic methoden_US
dc.subjectarticleen_US
dc.subjectatomic absorption spectrometryen_US
dc.subjectflame atomic absorption spectrometryen_US
dc.subjectflow injection analysisen_US
dc.subjectflow rateen_US
dc.subjecthealth hazarden_US
dc.subjecthumanen_US
dc.subjectsolid phase extractionen_US
dc.subjectspectrometryen_US
dc.subjectwater analysisen_US
dc.subjectwater contaminationen_US
dc.subjectwater samplingen_US
dc.titleOn-line solid phase extraction system for chromium determination in water samples by flow injection-flame atomic absorption spectrometryen_US
dc.typeArticleen_US
dc.identifier.volume35en_US
dc.identifier.issue9en_US
dc.identifier.startpage1519
dc.identifier.startpage1519en_US
dc.identifier.endpage1530en_US
dc.identifier.doi10.1081/AL-120006727-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-0036352699en_US
dc.identifier.wosWOS:000177716700006en_US
dc.identifier.scopusqualityQ2-
dc.ownerPamukkale_University-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.grantfulltextnone-
item.cerifentitytypePublications-
crisitem.author.dept17.01. Chemistry-
Appears in Collections:Fen-Edebiyat Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

40
checked on Nov 23, 2024

WEB OF SCIENCETM
Citations

42
checked on Nov 24, 2024

Page view(s)

32
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.