Title: | Pitfalls in the measurement of bone mineral density by the dual-energy X-ray absorptiometric method | Authors: | Suna Kıraç, Fatma Yüksel, Doğangün Taşkaya Yaylalı, Olga |
Keywords: | Artifact Dual-Energy X-Ray Absorptiometry Osteoporosis barium sulfate adult aged analytical error article artifact bone atrophy bone density calcification case report computer assisted tomography contrast enhancement dual energy X ray absorptiometry female human lumbar vertebra male osteoporosis Adult Aged Artifacts Barium Sulfate Bone Density Calcinosis Contrast Media Densitometry, X-Ray Female Humans Lumbar Vertebrae Male Tomography, X-Ray Computed |
Abstract: | The authors describe two patients with unusual artifacts superimposed on the lumbar vertebrae on dual-energy X-ray absorptiometry (DXA) spine images, especially on the lateral spine scans. In one patient, a contrast agent (barium sulfate) administered to obtain abdominal computed tomographic (CT) images was responsible for a pitfall during bone mineral density measurement. In the second patient, large calcified lesions within the liver and spleen located near the spine resulted in a false increase in bone mineral density (BMD) values. | URI: | https://hdl.handle.net/11499/5458 https://doi.org/10.1097/00003072-200110000-00019 |
ISSN: | 0363-9762 |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
7
checked on Nov 23, 2024
WEB OF SCIENCETM
Citations
6
checked on Nov 22, 2024
Page view(s)
40
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.