Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/5461
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTanyalçin, T.-
dc.contributor.authorKutay, F.Z.-
dc.contributor.authorAslan, Diler-
dc.date.accessioned2019-08-16T11:47:28Z
dc.date.available2019-08-16T11:47:28Z
dc.date.issued2001-
dc.identifier.issn0949-1775-
dc.identifier.urihttps://hdl.handle.net/11499/5461-
dc.identifier.urihttps://doi.org/10.1007/s007690100383-
dc.description.abstractIt is particularly important, when analyzing biological material, for the measurement procedure to be specific to the analyte and not to suffer interference by the matrix effect. Tissue fraction studies also require rapid and accurate methods to estimate the concentration of protein in solutions as well as many measurement methods used in medical laboratories. The design of this study is based on a comparison of the Lowry and the bicinchoninic acid (BCA) methods for the measurement of the total protein concentrations of rat liver subcellular fractions. In our experiment, subcellular fractions enriched in peroxisomes (POs) obtained by differential centrifugation were then further separated by means of density gradient centrifugation. We performed the protein measurement assays on all fractions obtained during the purification steps. The protein contents of the fractions obtained were determined by the two methods. The method comparison statistics were performed by linear Deming regression analysis and Altman and Bland bias plot. The regression equation was unacceptable, indicating that the last three fractions separated by means of Nycodenz discontinuous density gradient centrifugation gave remarkably divergent results. For the Lowry method, the Nycodenz effect could not be eliminated with the use of interference blank. In addition to Nycodenz, the potentially interfering compound used in the isolation procedure as isolation medium was 3-(morpholino)propane sulfonic acid (MOPS). In decreased concentrations of MOPS (10 mM), interference blank should be used for correct measurement with Lowry, but in practical use 10 mM does not provide buffering potency. In the BCA method, interference blank correction seemed to eliminate the measurement error in all concentrations of Nycodenz. There was no MOPS effect on the BCA measurement assay. Referring to deviations as sample-inherent matrix effects, we concluded that not only one, but more measurement methods should be used in order to make a correct protein measurement.en_US
dc.language.isoenen_US
dc.relation.ispartofAccreditation and Quality Assuranceen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBicinchoninic aciden_US
dc.subjectLowryen_US
dc.subjectProtein analysisen_US
dc.titleInterference study should be performed for every protein measurement method useden_US
dc.typeArticleen_US
dc.identifier.volume6en_US
dc.identifier.issue9-10en_US
dc.identifier.startpage427
dc.identifier.startpage427en_US
dc.identifier.endpage430en_US
dc.identifier.doi10.1007/s007690100383-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-0035438139en_US
dc.identifier.wosWOS:000171326300010en_US
dc.identifier.scopusqualityQ1-
dc.ownerPamukkale_University-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
crisitem.author.dept14.03. Basic Medical Sciences-
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Sep 16, 2024

WEB OF SCIENCETM
Citations

3
checked on Sep 24, 2024

Page view(s)

36
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.