Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/57128
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorÖzbey İpek, Hilal-
dc.contributor.authorGüngör İlhan, Gül Melikeen_US
dc.date.accessioned2024-05-16T11:20:03Z-
dc.date.available2024-05-16T11:20:03Z-
dc.date.issued2023en_US
dc.identifier.urihttps://hdl.handle.net/11499/57128-
dc.descriptionBu çalışma Pamukkale Üniversitesi Bilimsel Araştırma Projeleri Koordinasyon Birimi tarafından (Proje No: 2022DİŞF004) desteklenmiştiren_US
dc.description.abstractAmaç: Bu çalışmanın amacı; süt azı dişlerinde bilgisayar destekli tasarım ve üretim (CAD/CAM) sistemi kullanılarak farklı siman aralıklarında elde edilen zirkonya kuronların kırılma dayanımlarına farklı yapıştırma simanlarının etkisinin in vitro koşullarda değerlendirilmesidir. Yöntem: Toplamda 40 adet çekilmiş süt II. azı dişi, her bir grupta 10 diş olmak üzere 4 gruba ayrılmıştır. Preparasyonları tamamlanan dişler akrilik bloklara gömülmüştür. Kuronlar, CAD/CAM sisteminde 100 μm ve 200 μm oklüzal siman aralıklarında olmak üzere zirkonya bloklardan (InCoris TZI C, Sirona Dental Systems, GmbH, Bensheim, Almanya) üretilmiştir (n=20). Her bir grup kendi içerisinde cam iyonomer siman ve adeziv siman ile yapıştırılmak üzere iki gruba ayrılmıştır (n=10). Simantasyondan sonra örnekler kırılma testine kadar distile suda bekletilmiştir. Tüm örneklere 10 mm/dk hızda universal test cihazı ile yük uygulanmıştır. Her bir örneğin kırılma yükü Newton (N) cinsinden ölçülüp kaydedilmiştir. Elde edilen verilerin istatistiksel analizi NCSS (Number Cruncher Statistical System) 2007 Statistical Software (Utah, ABD) paket programı ile yapılmıştır. Bulgular: Çalıştığımız simanlar ve siman aralıklarının zirkonya kuronların kırılma dayanımı üzerine etkisinin istatistiksel olarak anlamlı olmadığı görülmüştür (p>0,05). En yüksek kırılma değeri ortalaması, 100 μm siman aralığında ve adeziv rezin siman kullanılan grupta görülmüştür. Sonuç: Bu çalışmanın sınırları içerisinde, süt dişlerine uygulanan CAD/CAM zirkonya kuronların kırılma dayanımları değerlerinin yüksek olduğu söylenebilir. Uygulanan siman aralıkları değerleri ve simanlar birbirlerinin alternatifi olarak kullanılabilir.en_US
dc.description.abstractObjective: The aim of this study is to evaluate the effect of different adhesive cements on the fracture strenghts of zirconia crowns obtained using the computer aided design/ computer aided manufacturing (CAD/CAM) system in primary molars at different cement intervals under in vitro conditions. Method: A total of forty extracted primary second molars were divided into four groups, each containing 10 teeth. Prepared teeth were embedded in acrylic blocks. Crowns were fabricated with computer aided design/computer aided manufacturing (CAD/CAM) system at 100 μm and 200 μm cement spacing. Each cement spacing group was further divided into two equal subgroups for cementation with glass ionomer cement and adhesive resin cement (n=10). After cementation, samples were stored in distilled water until fracture testing. Universal testing machine applied a load at a crosshead speed of 10 mm/min. The fracture load of each specimen was measured and recorded in Newtons (N). The statistical analysis of the obtained data was performed using the NCSS (Number Cruncher Statistical System) 2007 Statistical Software package program (Utah, USA). Results: It was observed that the different cements and cement spacing did not have a statistically significant effect on the fracture strength of zirconia crowns (p>0.05). The highest mean fracture load value was observed in the group where adhesive resin cement was used at a 100 μm cement spacing. Conclusion: Within the limitations of this study, it can be stated that the fracture resistance values of CAD/CAM zirconia crowns applied to primary teeth are high. The values of the applied cement spacings and the cements can be used as alternatives to each other.en_US
dc.language.isotren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKırılma dayanımıen_US
dc.subjectmonolitik CAD/CAM zirkonya kuronen_US
dc.subjectsiman aralığıen_US
dc.subjectsimanen_US
dc.subjectFracture strengthen_US
dc.subjectmonolithic zirconia crownen_US
dc.subjectcement spacingen_US
dc.titleSüt dişlerinde CAD/CAM ile üretilmiş zirkonya kuronların kırılma yükünün in vitro olarak değerlendirilmesi: İki farklı siman tipi ve aralığının karşılaştırılmasıen_US
dc.typeSpecialty Thesisen_US
dc.relation.publicationcategoryTezen_US
dc.contributor.affiliation#Pamukkale Üniversitesi#en_US
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeSpecialty Thesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.languageiso639-1tr-
Appears in Collections:Diş Hekimliği Fakültesi Tez Koleksiyonu
Files in This Item:
File Description SizeFormat 
10589361.pdf2.75 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

92
checked on Aug 24, 2024

Download(s)

54
checked on Aug 24, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.