Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/58241
Title: Evaluation of Ema, Töllner and Rodwell scores in the diagnosis of neonatal sepsis
Other Titles: Yenidoğan sepsis tanısında Ema, Töllner ve Rodwell skorlarının değerlendirilmesi
Authors: Özdemir, Ö.M.A.
Erdal, B.
Turgut, M.
Keywords: EMA
newborn
Rodwell
Sepsis
Töllner
Publisher: Pamukkale University
Abstract: Purpose: There are no specific signs, symptoms and rapid laboratory tests to definitively diagnose sepsis in the neonatal period. Therefore, in this study, we planned to investigate the clinical adequacy and reliability of EMA (European Medicines Agency), Töllner and Rodwell hematological scoring in the early diagnosis of neonatal sepsis. Materials and methods: EMA, Töllner and Rodwell hematological scoring was performed on each patient. Complete blood count, peripheral smear, C-reactive protein, procalcitonin, blood gas and blood sugar values of newborn babies with suspected sepsis were recorded, blood culture, urine culture and cerebrospinal fluid examination and cultures taken when necessary were evaluated. Using statistical analysis, the 'Positive Expected Value and Negative Expected Values' ratios of the scores were obtained, and the performance results were examined. Results: 95 newborns with a preliminary clinical diagnosis of sepsis were included in the study. These babies were divided into two groups: clinical (n:71) and proven sepsis (n:24) according to blood culture results. Positive and negative predictive values of scoring systems in definitive sepsis diagnosis; for EMA respectively; 21.5%, 56.3% for Töllner; It was determined as 31.3%, 77.8%, and 100%, 77.8% for Rodwell. Conclusion: Our study showed that clinician opinion and standard laboratory tests are limited in the diagnosis of neonatal sepsis, and Rodwell hematological scoring is more prominent in recognizing proven sepsis compared to the other two scores. © 2024, Pamukkale University. All rights reserved.
URI: https://doi.org/10.31362/patd.1457265
https://search.trdizin.gov.tr/tr/yayin/detay/1275063
https://hdl.handle.net/11499/58241
ISSN: 1309-9833
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection

Files in This Item:
File SizeFormat 
Evaluation of Ema.pdf827.78 kBAdobe PDFView/Open
Show full item record



CORE Recommender

Page view(s)

12
checked on Jan 21, 2025

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.