Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/5844
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Köroğlu, Selim | - |
dc.contributor.author | Sergeant, P. | - |
dc.contributor.author | Sabariego, R.V. | - |
dc.contributor.author | Dang, V.Q. | - |
dc.contributor.author | De Wulf, M. | - |
dc.date.accessioned | 2019-08-16T12:02:49Z | |
dc.date.available | 2019-08-16T12:02:49Z | |
dc.date.issued | 2011 | - |
dc.identifier.issn | 1751-8660 | - |
dc.identifier.uri | https://hdl.handle.net/11499/5844 | - |
dc.identifier.uri | https://doi.org/10.1049/iet-epa.2011.0081 | - |
dc.description.abstract | The shielding of buried three-phase high-voltage power lines can be done by placing them in conducting ferromagnetic U-shaped gutters covered with plates. In case of a perfect electrical contact between adjacent gutters and between adjacent cover plates, induced currents in the shield efficiently reduce the magnetic field generated by the cables. As however a perfect contact cannot be guaranteed, in practice, it is useful to quantify the effect of a defective electrical contact on the field reduction. From two-dimensional/three-dimensional finite element computations and experiments, the influence of the contact resistance on the shielding efficiency is investigated, as a function of the ratio of axial length to height of the shield elements. Furthermore, the effect of other parameters on the shielding efficiency is studied: the ratio of axial length to height, a parasitic air gap between the gutter and the cover plate and the type of the shield material. It was found that a low contact resistance deteriorates much more the shielding in case of an aluminium shield than in case of a steel shield. As expected, the effect is larger for shield elements with relatively short axial length with regard to the other dimensions. Nevertheless, the effect remains quite significant for aluminium shields with practically convenient dimensions. © 2011 The Institution of Engineering and Technology. | en_US |
dc.language.iso | en | en_US |
dc.relation.ispartof | IET Electric Power Applications | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Air-gaps | en_US |
dc.subject | Axial length | en_US |
dc.subject | Cover plate | en_US |
dc.subject | Electrical contacts | en_US |
dc.subject | Finite element computations | en_US |
dc.subject | High voltage cable | en_US |
dc.subject | High-voltage power line | en_US |
dc.subject | Perfect contact | en_US |
dc.subject | Shielding efficiency | en_US |
dc.subject | U-shaped | en_US |
dc.subject | Aluminum | en_US |
dc.subject | Cables | en_US |
dc.subject | Contact resistance | en_US |
dc.subject | Efficiency | en_US |
dc.subject | Electric contacts | en_US |
dc.subject | Magnetic fields | en_US |
dc.subject | Roofs | en_US |
dc.subject | Magnetic shielding | en_US |
dc.title | Influence of contact resistance on shielding efficiency of shielding gutters for high-voltage cables | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 5 | en_US |
dc.identifier.issue | 9 | en_US |
dc.identifier.startpage | 715 | |
dc.identifier.startpage | 715 | en_US |
dc.identifier.endpage | 720 | en_US |
dc.authorid | 0000-0001-8178-3227 | - |
dc.identifier.doi | 10.1049/iet-epa.2011.0081 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopus | 2-s2.0-80155140202 | en_US |
dc.identifier.wos | WOS:000296704000006 | en_US |
dc.identifier.scopusquality | Q1 | - |
dc.owner | Pamukkale University | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 10.04. Electrical-Electronics Engineering | - |
Appears in Collections: | Mühendislik Fakültesi Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
8
checked on Mar 29, 2025
WEB OF SCIENCETM
Citations
3
checked on Apr 2, 2025
Page view(s)
52
checked on Mar 4, 2025
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.