Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/59276
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Altınok Uygun, L. | - |
dc.contributor.author | Akgül, N. | - |
dc.date.accessioned | 2025-03-22T21:37:09Z | - |
dc.date.available | 2025-03-22T21:37:09Z | - |
dc.date.issued | 2021 | - |
dc.identifier.issn | 2322-4150 | - |
dc.identifier.uri | https://doi.org/10.22038/JDMT.2021.57660.1443 | - |
dc.identifier.uri | https://hdl.handle.net/11499/59276 | - |
dc.description.abstract | Introduction: The aim was to evaluate the polymerization properties of bulk-fill composite resins in terms of the degree of conversion (%DC), Vickers hardness (HV). SonicFill (SF, Kerr, CA, USA), Tetric Evo Ceram Bulk-Fill (TECBF, Ivoclar Vivadent Schaan, Lichtenstein), and X-trafil (XTF, Voco GmbH, Cuxhaven, Germany) were investigated. Methods: The samples prepared from composites (n = 10) were polymerized via three different curing modes (standard mode: 20 s, high-power mode: 12 s, extra power mode: 6 s) using a polywave LED. %DC was determined by FTIR-ATR-spectroscopy. HV was measured at the top and bottom of the specimens. Data were analyzed by two way ANOVA, and Bonferroni’s post-hoc respectively (α=0.05). Results: Except TECBF (%41.10 ± 3.1) in three different curing modes, all materials showed no significant inferior %DC. In all curing modes, the highest hardness ratio was found in XTF (0.84 ± 0.03 GPa), and the lowest hardness ratio was found in the TECBF (0.78 ± 0.02GPa). In the cases where the extra power mode of the Valo Led was applied, the lowest degree of conversion and hardness were also measured. Conclusion: It has been observed that the examined properties of some tested materials change with the curing time and power of the light and however, the results are dependent on the material. Extra power mode of the Valo Led negatively affected high viscosity bulk-fill composites in terms of their polymerization properties. © 2021, Mashhad University of Medical Sciences. All rights reserved. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Mashhad University of Medical Sciences | en_US |
dc.relation.ispartof | Journal of Dental Materials and Techniques | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Bulk-Fill | en_US |
dc.subject | Degree Of Conversion | en_US |
dc.subject | Light Curing | en_US |
dc.subject | Resin Composite | en_US |
dc.subject | Vickers Hardness | en_US |
dc.title | Evaluation of the Polymerization Properties of Bulk-Fill Composite Resins | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 10 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 164 | en_US |
dc.identifier.endpage | 172 | en_US |
dc.department | Pamukkale University | en_US |
dc.identifier.doi | 10.22038/JDMT.2021.57660.1443 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorscopusid | 57217289771 | - |
dc.authorscopusid | 6506373608 | - |
dc.identifier.scopus | 2-s2.0-85186452867 | - |
dc.identifier.scopusquality | Q4 | - |
dc.identifier.wosquality | N/A | - |
item.openairetype | Article | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
crisitem.author.dept | 06.01. Clinical Sciences | - |
Appears in Collections: | Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.