dc.description.abstractThe electromagnetic losses and shielding eficiency of shields for a buried three phase high voltage cable are studied for several shielding configurations. The shields are U-shaped gutters covered with plates, and the power cables are positioned either in trefoil or in flat configuration. The shielding eficiency and the losses are compared for shields with the same geometry but several shielding materials: aluminium, and two ferromagnetic steel grades. The numerical models are validated with experimental results. From the experiments, it is observed that the average reducing factor of the flux density is about 7 with the flat cable configuration while the average reducing factor of the flux density is about 5 with the trefoil cable configuration. But the power losses in the DX52 shield for trefoil configuration is about 40% lower compared to the flat configuration. In case of trefoil configuration, the losses are 12.14W/m per meter length in the shield for a current of 750 A. Next to the shield material and the cable configuration, the paper investigates the influence of several parameters on both the shielding eficiency and the losses: the size of the shield, the current amplitude in the cable and the thickness of the shield.en_US
dc.language.isoenen_US
dc.publisherElectromagnetics Academyen_US
dc.relation.ispartofProgress in Electromagnetics Researchen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCablesen_US
dc.subjectShieldingen_US
dc.subjectCurrent amplitudeen_US
dc.subjectElectromagnetic lossen_US
dc.subjectFerromagnetic steelen_US
dc.subjectFlux densitiesen_US
dc.subjectHigh voltage cableen_US
dc.subjectPower cablesen_US
dc.subjectPower-lossesen_US
dc.subjectShielding materialsen_US
dc.subjectElectromagnetic shieldingen_US
dc.titleElectromagnetic losses in magnetic shields for buried high voltage cablesen_US
dc.typeArticleen_US
dc.identifier.volume115en_US
dc.identifier.startpage441
dc.identifier.startpage441en_US
dc.identifier.endpage460en_US
dc.authorid0000-0001-8178-3227-
dc.identifier.doi10.2528/PIER11022206-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-79955533330en_US
dc.identifier.wosWOS:000289884000026en_US
dc.identifier.scopusqualityQ1-
dc.ownerPamukkale University-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextopen-
crisitem.author.dept10.04. Electrical-Electronics Engineering-
Appears in Collections:Mühendislik Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
26.11022206.pdf479.57 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

11
checked on Nov 16, 2024

WEB OF SCIENCETM
Citations

9
checked on Nov 21, 2024

Page view(s)

46
checked on Aug 24, 2024

Download(s)

22
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.