Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/6516
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Karabacak, Rasim | - |
dc.contributor.author | Güven Acar, Şengül | - |
dc.date.accessioned | 2019-08-16T12:08:10Z | |
dc.date.available | 2019-08-16T12:08:10Z | |
dc.date.issued | 2010 | - |
dc.identifier.issn | 1556-7036 | - |
dc.identifier.uri | https://hdl.handle.net/11499/6516 | - |
dc.identifier.uri | https://doi.org/10.1080/15567030802654061 | - |
dc.description.abstract | The ground source heat pump system is installed at Pamukkale University in Denizli, Turkey. The U-bend ground heat exchanger pipe length of 225 m was buried in soil at 110 m depth. In the 2007-2008 heating season, performance coefficients of the heat pump and the system were determined in the range of 2.5-4.2 and 2.03-2.66, respectively. The values of solar radiation, external temperature, relative humidity, and wind speed were measured continuously. The relations of performance coefficients of ground source heat pump according to the meteorological data including solar radiation, wind speed, relative humidity, and external temperature with this experiment was revealed exactly. The results of this study fulfill the lack in the literature. | en_US |
dc.language.iso | en | en_US |
dc.relation.ispartof | Energy Sources, Part A: Recovery, Utilization and Environmental Effects | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Borehole | en_US |
dc.subject | Ground heat exchanger | en_US |
dc.subject | Ground source heat pump | en_US |
dc.subject | Ground thermal conductivity | en_US |
dc.subject | Environmental conditions | en_US |
dc.subject | External temperature | en_US |
dc.subject | Ground heat exchangers | en_US |
dc.subject | Ground source heat pump systems | en_US |
dc.subject | Heat pumps | en_US |
dc.subject | Heating season | en_US |
dc.subject | Meteorological data | en_US |
dc.subject | Performance coefficients | en_US |
dc.subject | Relative humidities | en_US |
dc.subject | Thermal performance analysis | en_US |
dc.subject | Wind speed | en_US |
dc.subject | Atmospheric humidity | en_US |
dc.subject | Moisture | en_US |
dc.subject | Pumps | en_US |
dc.subject | Solar radiation | en_US |
dc.subject | Sun | en_US |
dc.subject | Thermal conductivity | en_US |
dc.subject | Thermoanalysis | en_US |
dc.subject | Wind effects | en_US |
dc.subject | Heat pump systems | en_US |
dc.title | The experimental thermal performance analysis of the ground source heat pump system dependent on environmental conditions | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 32 | en_US |
dc.identifier.issue | 12 | en_US |
dc.identifier.startpage | 1142 | |
dc.identifier.startpage | 1142 | en_US |
dc.identifier.endpage | 1158 | en_US |
dc.authorid | 0000-0002-4485-1945 | - |
dc.identifier.doi | 10.1080/15567030802654061 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopus | 2-s2.0-77951151511 | en_US |
dc.identifier.wos | WOS:000277488900008 | en_US |
dc.identifier.scopusquality | Q2 | - |
dc.owner | Pamukkale University | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.fulltext | No Fulltext | - |
crisitem.author.dept | 10.07. Mechanical Engineering | - |
crisitem.author.dept | 20.02. Metallurgical And Materials Engineering | - |
Appears in Collections: | Mühendislik Fakültesi Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
4
checked on Nov 23, 2024
WEB OF SCIENCETM
Citations
4
checked on Nov 26, 2024
Page view(s)
36
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.