Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/6665
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Divrikli, Ümit. | - |
dc.contributor.author | Akdoğan, Abdullah. | - |
dc.contributor.author | Soylak, M. | - |
dc.contributor.author | Elci, Latif. | - |
dc.date.accessioned | 2019-08-16T12:09:29Z | |
dc.date.available | 2019-08-16T12:09:29Z | |
dc.date.issued | 2009 | - |
dc.identifier.issn | 0039-9140 | - |
dc.identifier.uri | https://hdl.handle.net/11499/6665 | - |
dc.identifier.uri | https://doi.org/10.1016/j.talanta.2009.05.046 | - |
dc.description.abstract | The present paper proposes a preconcentration procedure for phosphorus determination by using ultraviolet-visible spectrophotometer. It is based on the formation of phosphomolybdate and its reduction to molybdenum blue. Phosphorus extraction as phosphomolybdenum blue complex was performed onto Amberlite XAD-4. The optimization step was carried out using two-level full factorial design. Three variables (resin amount, sample volume, flow rate) were regarded as factors in the optimization. The relative standard deviation was 2% at 0.08 µg mL-1. The limit of detection was found to be 2.23 µg L-1 (N = 15). The proposed solid-phase extraction procedure was applied to phosphorus in some fruit leaves, natural waters, and a standard reference material (SRM 1515 apple leaves). © 2009 Elsevier B.V. All rights reserved. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Talanta | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Amberlite XAD-4 | en_US |
dc.subject | Phosphorus | en_US |
dc.subject | Preconcentration | en_US |
dc.subject | Spectrophotometry | en_US |
dc.subject | Extraction | en_US |
dc.subject | Phase separation | en_US |
dc.subject | Spectrophotometers | en_US |
dc.subject | Multivariate optimization | en_US |
dc.subject | Phosphorus determination | en_US |
dc.subject | Pre-concentration | en_US |
dc.subject | Pre-concentration procedures | en_US |
dc.subject | Relative standard deviations | en_US |
dc.subject | Standard reference material | en_US |
dc.subject | Ultraviolet visible spectrophotometer | en_US |
dc.subject | Water analysis | en_US |
dc.title | Factorial design for multivariate optimization of preconcentration system for spectrophotometric phosphorus determination | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 79 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.startpage | 1287 | |
dc.identifier.startpage | 1287 | en_US |
dc.identifier.endpage | 1291 | en_US |
dc.authorid | 0000-0003-3419-9903 | - |
dc.authorid | 0000-0002-7120-4380 | - |
dc.identifier.doi | 10.1016/j.talanta.2009.05.046 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 19635361 | en_US |
dc.identifier.scopus | 2-s2.0-67651001711 | en_US |
dc.identifier.wos | WOS:000269288400017 | en_US |
dc.identifier.scopusquality | Q1 | - |
dc.owner | Pamukkale University | - |
item.cerifentitytype | Publications | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.openairetype | Article | - |
crisitem.author.dept | 17.01. Chemistry | - |
crisitem.author.dept | 17.01. Chemistry | - |
crisitem.author.dept | 17.01. Chemistry | - |
Appears in Collections: | Fen-Edebiyat Fakültesi Koleksiyonu PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
24
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
24
checked on Nov 21, 2024
Page view(s)
62
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.