Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/6665
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDivrikli, Ümit.-
dc.contributor.authorAkdoğan, Abdullah.-
dc.contributor.authorSoylak, M.-
dc.contributor.authorElci, Latif.-
dc.date.accessioned2019-08-16T12:09:29Z
dc.date.available2019-08-16T12:09:29Z
dc.date.issued2009-
dc.identifier.issn0039-9140-
dc.identifier.urihttps://hdl.handle.net/11499/6665-
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2009.05.046-
dc.description.abstractThe present paper proposes a preconcentration procedure for phosphorus determination by using ultraviolet-visible spectrophotometer. It is based on the formation of phosphomolybdate and its reduction to molybdenum blue. Phosphorus extraction as phosphomolybdenum blue complex was performed onto Amberlite XAD-4. The optimization step was carried out using two-level full factorial design. Three variables (resin amount, sample volume, flow rate) were regarded as factors in the optimization. The relative standard deviation was 2% at 0.08 µg mL-1. The limit of detection was found to be 2.23 µg L-1 (N = 15). The proposed solid-phase extraction procedure was applied to phosphorus in some fruit leaves, natural waters, and a standard reference material (SRM 1515 apple leaves). © 2009 Elsevier B.V. All rights reserved.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofTalantaen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAmberlite XAD-4en_US
dc.subjectPhosphorusen_US
dc.subjectPreconcentrationen_US
dc.subjectSpectrophotometryen_US
dc.subjectExtractionen_US
dc.subjectPhase separationen_US
dc.subjectSpectrophotometersen_US
dc.subjectMultivariate optimizationen_US
dc.subjectPhosphorus determinationen_US
dc.subjectPre-concentrationen_US
dc.subjectPre-concentration proceduresen_US
dc.subjectRelative standard deviationsen_US
dc.subjectStandard reference materialen_US
dc.subjectUltraviolet visible spectrophotometeren_US
dc.subjectWater analysisen_US
dc.titleFactorial design for multivariate optimization of preconcentration system for spectrophotometric phosphorus determinationen_US
dc.typeArticleen_US
dc.identifier.volume79en_US
dc.identifier.issue5en_US
dc.identifier.startpage1287
dc.identifier.startpage1287en_US
dc.identifier.endpage1291en_US
dc.authorid0000-0003-3419-9903-
dc.authorid0000-0002-7120-4380-
dc.identifier.doi10.1016/j.talanta.2009.05.046-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid19635361en_US
dc.identifier.scopus2-s2.0-67651001711en_US
dc.identifier.wosWOS:000269288400017en_US
dc.identifier.scopusqualityQ1-
dc.ownerPamukkale University-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.openairetypeArticle-
crisitem.author.dept17.01. Chemistry-
crisitem.author.dept17.01. Chemistry-
crisitem.author.dept17.01. Chemistry-
Appears in Collections:Fen-Edebiyat Fakültesi Koleksiyonu
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

24
checked on Nov 16, 2024

WEB OF SCIENCETM
Citations

24
checked on Nov 21, 2024

Page view(s)

62
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.