dc.description.abstract | This study evaluates the seismic capacity of school buildings with the selected template designs constructed per pre-modern code in Turkey, considering non-linear behaviour of reinforced concrete components. Capacity curves of the investigated buildings were determined by pushover analyses conducted in two principal directions. Seismic capacity evaluation was carried out in accordance with the recently published Turkish Earthquake Code (2007) that has similarities with FEMA-356 guidelines. Based on capacity curves of school buildings, it was found that the effect of material quality and detailing on seismic capacity is especially apparent for buildings with no or a limited number of shear walls. Buildings with a certain number of shear walls are less affected by low material quality and detailing, emphasising the importance of shear walls, especially in countries where construction with poor detailing is a common problem. The outcome of the study indicates that the existing school buildings constructed per the pre-modern code far from satisfying the expected performance objectives of the recent code requirements, suggesting that urgent planning and response need to be put in action. | en_US |
dc.language.iso | en | en_US |
dc.publisher | ICE Publishing Ltd | en_US |
dc.relation.ispartof | Proceedings of the Institution of Civil Engineers: Structures and Buildings | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Codes of practice & standards | en_US |
dc.subject | Concrete structures | en_US |
dc.subject | Seismic engineering | en_US |
dc.subject | Codes (symbols) | en_US |
dc.subject | Concrete construction | en_US |
dc.subject | Developing countries | en_US |
dc.subject | Earthquakes | en_US |
dc.subject | Reinforced concrete | en_US |
dc.subject | School buildings | en_US |
dc.subject | Shear flow | en_US |
dc.subject | Shear walls | en_US |
dc.subject | Code requirements | en_US |
dc.subject | Codes of practice | en_US |
dc.subject | Nonlinear behaviours | en_US |
dc.subject | Performance objective | en_US |
dc.subject | Principal directions | en_US |
dc.subject | Push-over analysis | en_US |
dc.subject | Seismic capacity | en_US |
dc.subject | Seismic capacity evaluation | en_US |
dc.subject | Earthquake engineering | en_US |
dc.subject | architectural design | en_US |
dc.subject | building code | en_US |
dc.subject | concrete structure | en_US |
dc.subject | performance assessment | en_US |
dc.subject | reinforced concrete | en_US |
dc.subject | seismic design | en_US |
dc.subject | seismic response | en_US |
dc.subject | structural response | en_US |
dc.title | Seismic capacity evaluation of school buildings in Turkey | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 161 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 147 | |
dc.identifier.startpage | 147 | en_US |
dc.identifier.endpage | 159 | en_US |
dc.authorid | 0000-0001-6750-8632 | - |
dc.identifier.doi | 10.1680/stbu.2008.161.3.147 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopus | 2-s2.0-56649109621 | en_US |
dc.identifier.wos | WOS:000257056800005 | en_US |
dc.identifier.scopusquality | Q2 | - |
dc.owner | Pamukkale University | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.openairetype | Article | - |
crisitem.author.dept | 10.02. Civil Engineering | - |
Appears in Collections: | Mühendislik Fakültesi Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
15
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
12
checked on Nov 21, 2024
Page view(s)
62
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.