Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/7493
Title: | Significance of asymmetrical posteromedial and posterolateral femoral condylar chamfer cuts in total knee arthroplasty | Authors: | Güngör, Harun Reşit Ök, Nusret Agladioglu, K. Akkaya, S. Kiter, E. |
Keywords: | Alignment Knee arthroplasty MRI Posterior offset Rotation adult female femur human knee knee arthroplasty male nuclear magnetic resonance imaging procedures retrospective study rotation surgery theoretical model young adult Adult Arthroplasty, Replacement, Knee Female Femur Humans Knee Joint Magnetic Resonance Imaging Male Models, Theoretical Retrospective Studies Young Adult |
Publisher: | Springer Verlag | Abstract: | Purpose: Orthopedic surgeons remove more bone from the posteromedial femoral condyle than the posterolateral condyle to achieve the desired femoral component rotation. Here, the correlation between the asymmetry of chamfer cuts and femoral component rotation in total knee arthroplasty was determined. Methods: A model was built to simulate anterior chamfer cuts performed during total knee arthroplasty to measure posterior condylar offset. Right knee axial magnetic resonance imaging slices were examined from 280 consecutive patients (142 men, 138 women; mean age 31.4 ± 6.6 years). The anatomic and surgical transepicondylar axes, as well as the posterior condylar joint line, were drawn. Differences in the posteromedial and posterolateral offsets and the femoral rotation angles relative to the posterior joint line were measured. Results: The mean surgical femoral rotation angle was 4.8° ± 1.2°, and the mean posterior condylar offset difference was 4.4 ± 1 mm, with a strong correlation (p < 0.0001; r = 0.803). There was no statistically significant difference between genders. Linear regression analyses revealed that a 0.8-mm difference between the anteroposterior dimensions of the medial and lateral posterior condylar offsets corresponded to 1° of femoral external rotation (p < 0.0001, R2 = 0.645). Conclusion: The accuracy of the applied technique intra-operatively can be verified by correlating the asymmetry of posterior chamfer cuts with the achieved femoral component rotation, as determined by measuring the thicknesses of posterior chamfer cuts with a caliper. Technical errors can also be minimized by confirming the association between the femoral component rotation—as predicted by the posterior condylar offset difference—and the preoperatively measured femoral rotation angle. Level of evidence: II. © 2014, European Society of Sports Traumatology, Knee Surgery, Arthroscopy (ESSKA). |
URI: | https://hdl.handle.net/11499/7493 https://doi.org/10.1007/s00167-014-3342-5 |
ISSN: | 0942-2056 |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
5
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
4
checked on Nov 21, 2024
Page view(s)
50
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.