Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/7553
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPekel, Gökhan-
dc.contributor.authorÇetin, Ebru Nevin-
dc.contributor.authorAcer, S.-
dc.contributor.authorYagci, R.-
dc.contributor.authorAltintas, S.-
dc.contributor.authorOngun, G.T.-
dc.date.accessioned2019-08-16T12:30:21Z
dc.date.available2019-08-16T12:30:21Z
dc.date.issued2014-
dc.identifier.issn1556-9527-
dc.identifier.urihttps://hdl.handle.net/11499/7553-
dc.identifier.urihttps://doi.org/10.3109/15569527.2013.814137-
dc.description.abstractObjective: To evaluate the effects of chronic tobacco smoking on lens nucleus by Pentacam HR lens densitometry (LD) in young adults. Design: Prospective cross-sectional case series. Methods: Thirty subjects (23 M, 7 F) who were chronic cigarette smokers (?10 cigarettes/day for at least 2 years) (group 1) and another 30 subjects (23 M, 7 F) who did not smoke (group 2), were included in this study. The patients were matched for age and sex between the groups. The exclusion criteria were any history of ocular surgery, any systemic disorders and any ocular diseases except for mild refractive disorders. Lens densitometry measurements were done with the Pentacam HR (Oculus, Wetzlar, Germany). The Schirmer test and pachymetry measurements were also performed. Results: Mean age of the patients for both groups was 28.90±8.20 years (range: 18-40 years). Mean lens densitometry (LD) measurements of Group 1 (chronic cigarette smoking group) were higher than those of Group 2 (control group) in all LD techniques; however only mean ''peak'' LD measurements showed a statistically significant difference between these two groups (Group 1: 8.67±0.61, Group 2: 8.44±0.70, p=0.04). The mean Schirmer test value was 12.43±5.60mm in Group 1 and 13.00±4.26mm in Group 2 (p=0.55). The mean central corneal thickness (CCT) value was 564.23±34.61 mm in Group 1 and 550.47±32.94 mm in Group 2 (p=0.03). Discussion: The Pentacam HR LD seems to be an important option for the evaluation of lens nucleus in young adults, because it gives objective and quantitative data. Conclusion: Although chronic smoking increases lens nucleus density in young adults, the effect is not statistically significant when compared with the control group. © 2014 Informa Healthcare USA, Inc.en_US
dc.language.isoenen_US
dc.publisherInforma Healthcareen_US
dc.relation.ispartofCutaneous and Ocular Toxicologyen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCigarette smokingen_US
dc.subjectLens densitometryen_US
dc.subjectLens nucleusen_US
dc.subjectPentacam HRen_US
dc.subjectYoung adultsen_US
dc.subjectadulten_US
dc.subjectarticleen_US
dc.subjectcataracten_US
dc.subjectcataractogenesisen_US
dc.subjectcentral corneal thicknessen_US
dc.subjectclinical articleen_US
dc.subjectclinical assessmenten_US
dc.subjectcontrolled studyen_US
dc.subjectcorneal pachymetryen_US
dc.subjectcross-sectional studyen_US
dc.subjectdensitometryen_US
dc.subjectdiagnostic test accuracy studyen_US
dc.subjecteye examinationen_US
dc.subjectfemaleen_US
dc.subjecthumanen_US
dc.subjectlens densitometryen_US
dc.subjectlens nucleusen_US
dc.subjectmaleen_US
dc.subjectmeasurementen_US
dc.subjectophthalmic cameraen_US
dc.subjectparametersen_US
dc.subjectpredictive valueen_US
dc.subjectprospective studyen_US
dc.subjectSchirmer testen_US
dc.subjectsmokingen_US
dc.subjectyoung adulten_US
dc.subjectadolescenten_US
dc.subjectanatomy and histologyen_US
dc.subjectvisual system examinationen_US
dc.subjectAdolescenten_US
dc.subjectAdulten_US
dc.subjectCross-Sectional Studiesen_US
dc.subjectDensitometryen_US
dc.subjectDiagnostic Techniques, Ophthalmologicalen_US
dc.subjectFemaleen_US
dc.subjectHumansen_US
dc.subjectLens Nucleus, Crystallineen_US
dc.subjectMaleen_US
dc.subjectProspective Studiesen_US
dc.subjectSmokingen_US
dc.subjectYoung Adulten_US
dc.titleEffect of chronic smoking on lens nucleus as assessed by Pentacam HR lens densitometry in young adultsen_US
dc.typeArticleen_US
dc.identifier.volume33en_US
dc.identifier.issue2en_US
dc.identifier.startpage145
dc.identifier.startpage145en_US
dc.identifier.endpage149en_US
dc.authorid0000-0002-9509-8500-
dc.authorid0000-0002-2696-3425-
dc.identifier.doi10.3109/15569527.2013.814137-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid23865745en_US
dc.identifier.scopus2-s2.0-84901344454en_US
dc.identifier.wosWOS:000336731700013en_US
dc.identifier.scopusqualityQ3-
dc.ownerPamukkale University-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
crisitem.author.dept14.01. Surgical Medicine-
crisitem.author.dept14.01. Surgical Medicine-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

6
checked on Jul 29, 2024

WEB OF SCIENCETM
Citations

6
checked on Jul 28, 2024

Page view(s)

36
checked on Jul 31, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.