Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/7666
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pekel, Gökhan | - |
dc.contributor.author | Yagci, R. | - |
dc.contributor.author | Acer, S. | - |
dc.contributor.author | Özdemir, S. | - |
dc.contributor.author | Sayin, N. | - |
dc.date.accessioned | 2019-08-16T12:31:13Z | |
dc.date.available | 2019-08-16T12:31:13Z | |
dc.date.issued | 2014 | - |
dc.identifier.issn | 0196-8092 | - |
dc.identifier.uri | https://hdl.handle.net/11499/7666 | - |
dc.identifier.uri | https://doi.org/10.1002/lsm.22273 | - |
dc.description.abstract | Background and Objective Posterior capsular opacification (PCO) is the most frequent complication after cataract surgery. The most used method in order to disrupt the opacified posterior capsule is Nd-YAG laser posterior capsulotomy. Our aim was to evaluate the impact of Nd-YAG laser posterior capsulotomy on ocular pulse amplitude (OPA), central corneal thickness (CCT), corneal volume (CV), iridocorneal angle (ICA), and anterior chamber depth (ACD). Materials and Methods Thirty-three eyes of 30 pseudophakic patients who underwent Nd-YAG capsulotomy due to posterior capsule opacification, were included in this prospective cross-sectional consecutive case series. The OPA was measured with the Pascal dynamic contour tonometer. The CCT, CV, ICA, and ACD measurements were taken with the Scheimpflug imaging system (Pentacam HR). The examinations were performed preoperatively, and repeated at the postoperative first hour, week, and month. Results The mean OPA, ICA, and ACD values did not change statistically significantly after the posterior capsulotomy (P > 0.05). The mean CCT increased markedly and the mean CV increased slightly after one hour from the capsulotomy (P = 0.001 and P = 0.02, respectively), and then returned to the baseline values at the first week and first month visits (P > 0.05). Conclusions Nd:YAG capsulotomy does not significantly alter OPA, ICA, and ACD; but it causes temporary increase of CCT and CV in the short term. © 2014 Wiley Periodicals, Inc. | en_US |
dc.language.iso | en | en_US |
dc.publisher | John Wiley and Sons Inc. | en_US |
dc.relation.ispartof | Lasers in Surgery and Medicine | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | corneal volume | en_US |
dc.subject | dynamic contour tonometry | en_US |
dc.subject | iridocorneal angle | en_US |
dc.subject | laser capsulotomy | en_US |
dc.subject | posterior capsular opacification | en_US |
dc.subject | anterior eye chamber | en_US |
dc.subject | article | en_US |
dc.subject | capsulotomy | en_US |
dc.subject | cataract extraction | en_US |
dc.subject | central corneal thickness | en_US |
dc.subject | clinical article | en_US |
dc.subject | contact lens | en_US |
dc.subject | cross-sectional study | en_US |
dc.subject | dynamic contour tonometer | en_US |
dc.subject | eye | en_US |
dc.subject | follow up | en_US |
dc.subject | human | en_US |
dc.subject | imaging system | en_US |
dc.subject | intraocular pressure | en_US |
dc.subject | morphology | en_US |
dc.subject | neodymium YAG laser | en_US |
dc.subject | ophthalmic neodymium YAG laser | en_US |
dc.subject | posterior lens capsule | en_US |
dc.subject | postoperative complication | en_US |
dc.subject | priority journal | en_US |
dc.subject | prospective study | en_US |
dc.subject | pseudophakia | en_US |
dc.subject | Scheimpflug imaging system | en_US |
dc.subject | slit lamp | en_US |
dc.subject | tonometer | en_US |
dc.subject | treatment outcome | en_US |
dc.subject | visual acuity | en_US |
dc.subject | anatomy and histology | en_US |
dc.subject | anterior eye segment | en_US |
dc.subject | capsule opacification | en_US |
dc.subject | evaluation study | en_US |
dc.subject | female | en_US |
dc.subject | lens capsule | en_US |
dc.subject | male | en_US |
dc.subject | middle aged | en_US |
dc.subject | oculoplethysmography | en_US |
dc.subject | solid state laser | en_US |
dc.subject | therapeutic use | en_US |
dc.subject | Anterior Eye Segment | en_US |
dc.subject | Capsule Opacification | en_US |
dc.subject | Cross-Sectional Studies | en_US |
dc.subject | Female | en_US |
dc.subject | Humans | en_US |
dc.subject | Lasers, Solid-State | en_US |
dc.subject | Lens Capsule, Crystalline | en_US |
dc.subject | Male | en_US |
dc.subject | Middle Aged | en_US |
dc.subject | Prospective Studies | en_US |
dc.subject | Tonometry, Ocular | en_US |
dc.title | Evaluation of the impact of Nd:YAG laser posterior capsulotomy on ocular pulse amplitude and anterior segment morphology | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 46 | en_US |
dc.identifier.issue | 7 | en_US |
dc.identifier.startpage | 553 | |
dc.identifier.startpage | 553 | en_US |
dc.identifier.endpage | 557 | en_US |
dc.authorid | 0000-0002-9509-8500 | - |
dc.identifier.doi | 10.1002/lsm.22273 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 24986133 | en_US |
dc.identifier.scopus | 2-s2.0-84906354852 | en_US |
dc.identifier.wos | WOS:000340529500006 | en_US |
dc.identifier.scopusquality | Q1 | - |
dc.owner | Pamukkale University | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.openairetype | Article | - |
crisitem.author.dept | 14.01. Surgical Medicine | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
6
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
5
checked on Nov 21, 2024
Page view(s)
54
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.