Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/7721
Title: Batch and fixed-bed column studies of arsenic adsorption on the natural and modified clinoptilolite
Authors: Bilici Başkan, Meltem
Pala, A.
Keywords: Adsorption isotherm
Arsenate
Batch and column adsorption
Desorption
Zeolite
Adsorption capacities
Arsenate adsorption
Column adsorption
Freundlich isotherm
Initial concentration
Modified clinoptilolite
Performance experiment
Adsorption isotherms
Arsenic
Experiments
Pollution control
Zeolites
Adsorption
arsenic
arsenic acid
clinoptilolite
zeolite
adsorption
arsenate
concentration (composition)
desorption
pH
analytic method
article
batch process
concentration (parameters)
flow rate
isotherm
waste component removal
Abstract: The samples of natural and iron-modified clinoptilolite (GC, Na-GC, Fe1-GC, and Fe2-GC) were assessed as adsorbent for arsenate removal by batch and column studies. The influences of retention time, pH, adsorbent dosage, and initial arsenate concentration on the arsenate adsorption efficiency were investigated. The experiments demonstrated that Fe1-GC has the highest arsenate removal efficiency with the adsorption capacity of 8.4 ?g g?1 at equilibrium time of 60 min. Both the Fe1-GC and Fe2-GC removed arsenate effectively over the initial pH range 4-10. Adsorption capacity of Fe1-GC was adequately described by Freundlich isotherm. According to the results of the desorption performance experiments, the Fe1-GC was used six times until arsenic removal efficiency was reduced to 19 %. The adsorption percentage of arsenic increased with the diminish of initial concentration of arsenic and increase of adsorbent dose for all types of clinoptilolite. The column study demonstrated that Fe1-GC was achieved to reduce final arsenate of about 10 ?g L?1 or below for up to 300 bed volumes in a continuous flow mode. The results of this study show that Fe1-GC can be used as an alternative adsorbent for arsenate removal. © Springer Science+Business Media Dordrecht 2013.
URI: https://hdl.handle.net/11499/7721
https://doi.org/10.1007/s11270-013-1798-4
ISSN: 0049-6979
Appears in Collections:Mühendislik Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

SCOPUSTM   
Citations

27
checked on Dec 14, 2024

WEB OF SCIENCETM
Citations

23
checked on Dec 19, 2024

Page view(s)

34
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.