Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/7965
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUcar, C.-
dc.contributor.authorBaşkan, Meltem Bilici-
dc.contributor.authorPala, A.-
dc.date.accessioned2019-08-16T12:33:52Z-
dc.date.available2019-08-16T12:33:52Z-
dc.date.issued2013-
dc.identifier.issn0256-1115-
dc.identifier.urihttps://hdl.handle.net/11499/7965-
dc.identifier.urihttps://doi.org/10.1007/s11814-013-0128-2-
dc.description.abstractArsenic removal from drinking water was investigated using electrocoagulation (EC) followed by filtration. A sand filter was used to remove flocs generated in the EC process. Experiments were performed in a batch electrochemical reactor using iron electrodes with monopolar parallel electrode connection mode to assess their efficiency. The effects of several operating parameters on arsenic removal such as current density (1.5-9.0 mA cm-2), initial arsenic concentration (50-500 µg L-1), operating time (0-15 min), electrode surface area (266-665 cm2), and sodium chloride concentrations (0.01 and 0.02M) were examined. The EC process was able to decrease the residual arsenic concentration to less than 10 µg L-1. Optimum operating conditions were determined as an operating time of 5 min and current density of 4.5 mA cm-2 at pH of 7. The optimum electrode surface area for arsenic removal was found to be 266 cm2 taking into consideration cost effectiveness. The residual iron concentration increased with increasing residence time, and maximum residual iron value was measured as 287 µg L-1 for electrode surface area of 266 cm2. The addition of sodium chloride had no significant effect on residual arsenic concentration, but an increase in current density was observed. © 2013 Korean Institute of Chemical Engineers, Seoul, Korea.en_US
dc.language.isoenen_US
dc.relation.ispartofKorean Journal of Chemical Engineeringen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectArsenicen_US
dc.subjectDrinking Wateren_US
dc.subjectElectrocoagulationen_US
dc.subjectIron Concentrationen_US
dc.subjectIron Electrodesen_US
dc.titleArsenic removal from drinking water by electrocoagulation using iron electrodesen_US
dc.typeArticleen_US
dc.identifier.volume30en_US
dc.identifier.issue10en_US
dc.identifier.startpage1889-
dc.identifier.startpage1889en_US
dc.identifier.endpage1895en_US
dc.identifier.doi10.1007/s11814-013-0128-2-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-84884982793en_US
dc.identifier.wosWOS:000325237400009en_US
dc.identifier.scopusqualityQ2-
dc.ownerPamukkale University-
item.grantfulltextnone-
item.openairetypeArticle-
item.languageiso639-1en-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.dept10.01. Environmental Engineering-
Appears in Collections:Mühendislik Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

24
checked on Oct 13, 2024

WEB OF SCIENCETM
Citations

25
checked on Oct 14, 2024

Page view(s)

46
checked on Aug 24, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.