Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/8489
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKaçan, Erdal-
dc.contributor.authorÜlgen, Koray-
dc.contributor.authorKacan, Erkan-
dc.date.accessioned2019-08-16T12:41:12Z-
dc.date.available2019-08-16T12:41:12Z-
dc.date.issued2012-
dc.identifier.issn1300-1884-
dc.identifier.urihttps://hdl.handle.net/11499/8489-
dc.description.abstractScope of this study is, to examine the impacts of improvements made on building envelope and roof on existing buildings, to evaluate the waste gas emissions caused by the construction properties and energy consumption types of existing buildings. Calculations are done by creating model building that represents all existing building of which has 7.8, m height, 156 m 2 floor area, 3 stored and wooden framed single-glazed window system. Heating and cooling periods are taken up separately in different degree-day sections and optimum insulation thicknesses are obtained between 6 cm and 16 cm. Heating-cooling period of model building is 7 months-5 months for 1st DD section, 8 months-3 months for 2nd DD section, 10 months-2 months for 3th DD section and heating period is 10 months, no cooling period for 4th DD section. It is adopted that heating load is satisfied by natural gas, fuel-oil and coal and cooling load by electricity. Emission saving values which are dependent to fuel type and heating cooling period are determined between 28 % and 80 % for CO 2, 58 % and 80 % for SO 2 emissions. Results show that, dealing heating and cooling periods together in the analysis, produce effective solutions in order to ensure comfort conditions.en_US
dc.language.isotren_US
dc.relation.ispartofJournal of the Faculty of Engineering and Architecture of Gazi Universityen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCO 2-SO 2 emissionen_US
dc.subjectCoolingen_US
dc.subjectEnergy savingen_US
dc.subjectHeatingen_US
dc.subjectModel buildingen_US
dc.subjectOptimum insulationen_US
dc.subjectBuilding envelopesen_US
dc.subjectBuilding stocksen_US
dc.subjectComfort conditionsen_US
dc.subjectCooling loaden_US
dc.subjectEffective solutionen_US
dc.subjectEmission savingen_US
dc.subjectEnergetic effecten_US
dc.subjectFloor areasen_US
dc.subjectFuel typesen_US
dc.subjectHeating loaden_US
dc.subjectHeating perioden_US
dc.subjectWindow systemen_US
dc.subjectCarbon dioxideen_US
dc.subjectEnergy conservationen_US
dc.subjectEnergy utilizationen_US
dc.subjectGas emissionsen_US
dc.subjectInsulationen_US
dc.subjectModel buildingsen_US
dc.subjectRoofsen_US
dc.subjectSulfur dioxideen_US
dc.titleEnvironmental and energetic effects of insulation over the building stock in Turkeyen_US
dc.title.alternativeTürkiye'deki bina stokunda optimum yalitim uygulamasinin enerji ve çevre etkilerien_US
dc.typeArticleen_US
dc.identifier.volume27en_US
dc.identifier.issue3en_US
dc.identifier.startpage669-
dc.identifier.startpage669en_US
dc.identifier.endpage677en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-8486698414en_US
dc.identifier.wosWOS:000309469800023en_US
dc.identifier.scopusqualityQ2-
dc.ownerPamukkale University-
item.openairetypeArticle-
item.languageiso639-1tr-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.cerifentitytypePublications-
Appears in Collections:Denizli Teknik Bilimler Meslek Yüksekokulu Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

1
checked on Nov 22, 2024

Page view(s)

48
checked on Aug 24, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.