Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/8505
Title: Outcomes of posterior titanium spinal instrumentation in neuromuscular scoliosis patients
Authors: Oto, Murat
Holmes, L.
Rogers, K.
Yilmaz, G.
Yorgova, P.
Shah, S.A.
Keywords: Neuromuscular
Posterior spinal fusion
Scoliosis
Titanium
titanium
adolescent
adult
article
child
equipment
female
follow up
human
male
neuromuscular disease
radiography
retrospective study
scoliosis
spine
spine fusion
treatment outcome
Adolescent
Child
Female
Follow-Up Studies
Humans
Male
Neuromuscular Diseases
Retrospective Studies
Spinal Fusion
Spine
Treatment Outcome
Young Adult
Abstract: Objectives: In this study, we aimed to characterize the outcomes of posterior spinal fusion (PSF) using titanium instrumentation in neuromuscular scoliosis (NMS) patients with a special focus on deformity correction and correction maintenance. Patients and methods: Between 2002 and 2004, nine patients (5 girls and 4 boys; mean age 14.9±2.3 years; range 11 to 19 years) with NMS who underwent PSF using titanium instrumentation were retrospectively analyzed. The mean height at surgery was 154.6±14.2 cm (range, 136-173 cm) and the mean weight was 59.4±19.2 kg (range, 26-114 kg). The mean follow-up duration was 3.7 years (range, 2-5 years). Preoperative data included demographics, curve type, and surgical indication. Rod size, fusion levels, duration of the operation (min), estimated blood loss (cc), and length of stay in hospital (day) were also evaluated intraoperatively. Postoperative data included correction of deformity, maintenance of correction, and complications. Radiographic measurements were obtained from standing posterior-anterior and lateral spinal radiographs at preoperative, postoperative (at first week after standing; i.e. first erect) and last follow-up visits. The data obtained were analyzed using descriptive statistic methods (mean, standard deviation, median, frequency and percentage). Results: Dramatic improvements in the spinal deformities were observed in the patients with NMS who underwent PSF using titanium instrumentation. Mean preoperative Cobb angle was reduced from 69.7 degrees to 16.2 degrees at first erect following surgery (at first week; 77% correction). Two-year follow-up revealed that this correction sustained (mean 14.8 degrees). However, moderate to severe postoperative complications requiring careful monitoring were reported. Conclusion: Our study results showed that PSF with titanium instrumentation in pediatric NMS patients demonstrated satisfactory outcomes during the follow-up period. However, further large-scale studies with a long-term follow-up results are required to generalize the results regarding PSF using titanium instrumentation in these patients.
URI: https://hdl.handle.net/11499/8505
ISSN: 1305-8282
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
c85e78f7-4584-4d35-ae48-8a0cadffa0ac.pdf354.97 kBAdobe PDFView/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

4
checked on Nov 23, 2024

WEB OF SCIENCETM
Citations

4
checked on Nov 21, 2024

Page view(s)

46
checked on Aug 24, 2024

Download(s)

42
checked on Aug 24, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.