Please use this identifier to cite or link to this item:
https://hdl.handle.net/11499/8802
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Erken, Gülten | - |
dc.contributor.author | Bor Küçükatay, Melek | - |
dc.contributor.author | Turgut, Sebahat | - |
dc.contributor.author | Erken, H.A. | - |
dc.contributor.author | Çömlekçi, S. | - |
dc.contributor.author | Divrikli, Ümit | - |
dc.contributor.author | Genç, Osman | - |
dc.date.accessioned | 2019-08-16T12:47:27Z | - |
dc.date.available | 2019-08-16T12:47:27Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 2146-3123 | - |
dc.identifier.uri | https://hdl.handle.net/11499/8802 | - |
dc.identifier.uri | https://doi.org/10.5152/balkanmedj.2011.021 | - |
dc.description.abstract | Objective: The aim of this study was to investigate the effects of the electromagnetic field generated from the 1800 MHz radiofrequency radiation (EF) on erythrocyte rheological parameters and erythrocyte zinc levels. Material and Methods: Twenty-four male Wistar Albino rats were randomly grouped as follows: 1) two control groups and 2) study groups: i) Group A: EF exposed group (2.5 h/day for 30 days, the phone on stand-by), and ii) Group B: EF exposed group (2.5 min/day for 30 days, the phone ringing in silent mode). At the end of the experimental period erythrocyte rheological parameters such as erythrocyte deformability and aggregation were determined by an ectacytometer. Erythrocyte zinc level, which affects hemorheological parameters, was also measured by atomic absorption spectrophotometer. Results: Erythrocyte deformability was decreased in both study groups but the decrease in group A was not statistically significant. Exposure to EF did not have any significant effect on erythrocyte aggregation. On the other hand, erythrocyte zinc level was significantly reduced in both study groups. Conclusion: Exposure to EF may have decreased tissue oxygenation due to reduced erythrocyte deformability. Decrease in erythrocyte zinc level may have caused the impairment in erythrocyte deformability. © Trakya University Faculty of Medicine. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Galenos Publishing House | en_US |
dc.relation.ispartof | Balkan Medical Journal | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Electromagnetic field | en_US |
dc.subject | Erythrocyte aggregation | en_US |
dc.subject | Erythrocyte deformability | en_US |
dc.subject | Mobile phone | en_US |
dc.subject | Trace element | en_US |
dc.subject | zinc | en_US |
dc.subject | animal cell | en_US |
dc.subject | animal experiment | en_US |
dc.subject | article | en_US |
dc.subject | blood flow | en_US |
dc.subject | controlled study | en_US |
dc.subject | electromagnetic field | en_US |
dc.subject | erythrocyte aggregation | en_US |
dc.subject | erythrocyte deformability | en_US |
dc.subject | erythrocyte level | en_US |
dc.subject | erythrocyte parameters | en_US |
dc.subject | male | en_US |
dc.subject | mobile phone | en_US |
dc.subject | nonhuman | en_US |
dc.subject | radiofrequency radiation | en_US |
dc.subject | rat | en_US |
dc.title | The effects of electromagnetic fields generated from 1800 MHz cell phones on erythrocyte rheological parameters and zinc level in rats | en_US |
dc.title.alternative | 1800 MHz radyofrekans radyasyondan kaynaklanan elektromanyetik alanın eritrositlerin reolojik parametreleri ve cinko seviyeleri üzerindeki etkisi | en_US |
dc.type | Article | en_US |
dc.identifier.volume | 29 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 139 | - |
dc.identifier.startpage | 139 | en_US |
dc.identifier.endpage | 143 | en_US |
dc.identifier.doi | 10.5152/balkanmedj.2011.021 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.pmid | 25206983 | en_US |
dc.identifier.scopus | 2-s2.0-84863108272 | en_US |
dc.identifier.trdizinid | 143217 | en_US |
dc.identifier.wos | WOS:000315504700006 | en_US |
dc.identifier.scopusquality | Q3 | - |
dc.owner | Pamukkale University | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
crisitem.author.dept | 14.03. Basic Medical Sciences | - |
crisitem.author.dept | 14.03. Basic Medical Sciences | - |
crisitem.author.dept | 17.01. Chemistry | - |
crisitem.author.dept | 14.03. Basic Medical Sciences | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Tıp Fakültesi Koleksiyonu TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
pdf_BMJ_501.pdf | 202.68 kB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
2
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
2
checked on Nov 21, 2024
Page view(s)
62
checked on Aug 24, 2024
Download(s)
28
checked on Aug 24, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.