Please use this identifier to cite or link to this item: https://hdl.handle.net/11499/9296
Full metadata record
DC FieldValueLanguage
dc.contributor.authorİmamoğlu, Serhat-
dc.contributor.authorCelik, N.B.-
dc.contributor.authorSevim, M.S.-
dc.contributor.authorPekel, Gökhan-
dc.contributor.authorErcalik, N.Y.-
dc.contributor.authorTurkseven Kumral, E.-
dc.contributor.authorBardak, H.-
dc.date.accessioned2019-08-16T12:59:32Z
dc.date.available2019-08-16T12:59:32Z
dc.date.issued2017-
dc.identifier.issn1057-0829-
dc.identifier.urihttps://hdl.handle.net/11499/9296-
dc.identifier.urihttps://doi.org/10.1097/IJG.0000000000000675-
dc.description.abstractPurpose: To investigate the relationship between the Bruch membrane opening-minimum rim width (BMO-MRW) (global and temporal) parameters with spectral-domain optical coherence tomography (SD-OCT) and visual field (VF) sensitivity on the 10-2 test in patients with advanced glaucoma. Materials and Methods: This cross-sectional, observational study included a total of 33 eyes of 29 patients. To evaluate VF sensitivity, automated white-on-white perimetry was performed using a Humphrey field analyzer. The mean deviation (MD) and pattern SD values were used to characterize the degree of functional damage. BMO-MRW and peripapillary retinal nerve fiber layer thickness were obtained with SD-OCT. According to the Garway-Heath map and fovea and BMO axis, the 90 degrees temporal sector of the optic disc corresponding to the central VF was divided into upper and lower parts. Results: The upper and lower temporal BMO-MRW parameters showed stronger correlations with the MD parameters of their corresponding VFs when compared with both global and temporal MRW parameters. Global and temporal retinal nerve fiber layer thickness parameters were also correlated with global MD parameters. Conclusions: BMO-MRW measurements in the upper and lower parts of the 90 degrees temporal sector of the optic nerve head by SD-OCT and their corresponding VF sensitivity on the 10-2 test were found highly correlated. These BMO-MRW measurements could offer a means of predicting the status of visual hemifields in patients who are unable to undergo VF testing. Further longitudinal studies with larger series evaluating BMO-MRW parameters with SD-OCT are also needed to monitor progression in advanced glaucoma. © 2017 Wolters Kluwer Health, Inc. All rights reserved.en_US
dc.language.isoenen_US
dc.publisherLippincott Williams and Wilkinsen_US
dc.relation.ispartofJournal of Glaucomaen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectadvanced glaucomaen_US
dc.subjectThe Bruch membrane opening-minimum rim widthen_US
dc.subjectvisual fielden_US
dc.subjectadulten_US
dc.subjectageden_US
dc.subjectArticleen_US
dc.subjectBruch membraneen_US
dc.subjectclinical articleen_US
dc.subjectcorrelation analysisen_US
dc.subjectcross-sectional studyen_US
dc.subjectdisease courseen_US
dc.subjectfemaleen_US
dc.subjectglaucomaen_US
dc.subjectGoldmann applanation tonometeren_US
dc.subjecthumanen_US
dc.subjectHumphrey perimeteren_US
dc.subjectintraocular pressureen_US
dc.subjectmaleen_US
dc.subjectobservational studyen_US
dc.subjectoptic disken_US
dc.subjectperimetryen_US
dc.subjectpredictionen_US
dc.subjectpriority journalen_US
dc.subjectretinal nerve fiber layer thicknessen_US
dc.subjectslit lamp microscopyen_US
dc.subjectspectral domain optical coherence tomographyen_US
dc.subjectstructure activity relationen_US
dc.subjectvery elderlyen_US
dc.subjectvisual field defecten_US
dc.subjectdisease exacerbationen_US
dc.subjectmiddle ageden_US
dc.subjectnerve fiberen_US
dc.subjectoptical coherence tomographyen_US
dc.subjectpathologyen_US
dc.subjectpathophysiologyen_US
dc.subjectphysiologyen_US
dc.subjectproceduresen_US
dc.subjectretinaen_US
dc.subjectretina foveaen_US
dc.subjectvisual disorderen_US
dc.subjectAdulten_US
dc.subjectAgeden_US
dc.subjectAged, 80 and overen_US
dc.subjectBruch Membraneen_US
dc.subjectCross-Sectional Studiesen_US
dc.subjectDisease Progressionen_US
dc.subjectFemaleen_US
dc.subjectFovea Centralisen_US
dc.subjectGlaucomaen_US
dc.subjectHumansen_US
dc.subjectIntraocular Pressureen_US
dc.subjectMaleen_US
dc.subjectMiddle Ageden_US
dc.subjectNerve Fibersen_US
dc.subjectRetinaen_US
dc.subjectTomography, Optical Coherenceen_US
dc.subjectVision Disordersen_US
dc.subjectVisual Fieldsen_US
dc.titleStructure-function relationship between the bruch membrane opening-based minimum rim width and visual field defects in advanced glaucomaen_US
dc.typeArticleen_US
dc.relation.journalJournal of Glaucomaen_US
dc.identifier.volume26en_US
dc.identifier.issue6en_US
dc.identifier.startpage561en_US
dc.identifier.endpage565en_US
dc.authorid0000-0002-9509-8500-
dc.identifier.doi10.1097/IJG.0000000000000675-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid28394809en_US
dc.identifier.scopus2-s2.0-85017233736en_US
dc.identifier.wosWOS:000402524000021en_US
dc.identifier.scopusqualityQ1-
dc.ownerPamukkale University-
item.languageiso639-1en-
item.openairetypeArticle-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept14.01. Surgical Medicine-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Tıp Fakültesi Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

13
checked on Jun 29, 2024

WEB OF SCIENCETM
Citations

13
checked on Jul 10, 2024

Page view(s)

40
checked on May 27, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.